Non-invasive Electrical Impedance Tomography (EIT) and Electrical Impedance Spectroscopy (EIS) are emerging as promising techniques for real-time monitoring and quality assessment in food processing and agri-food applications. This study reviews recent advances in impedance-based sensing for fruit characterization and investigates the experimental implementation of multi-electrode impedance measurements for tomographic imaging. Particular attention is devoted to electrode configurations, electrode polarization effects, and equivalent circuit modeling. Experimental measurements were performed on yellow honeydew melon samples using a four-electrode configuration and a impedance analyzer Keysight E4990 (Keysight Technologies, Santa Rosa, USA) over the frequency range from 20 Hz to 1 MHz. The impedance spectra were validated through Kramers–Kronig consistency tests and interpolated using several fractional-order equivalent circuit models, including single-Cole, double-Cole, and Hayden-based models. The results show that four-electrode measurements are less sensitive to electrode-sample interface artifacts than conventional two-electrode approaches, thereby providing a more reliable estimate of the sample impedance, particularly at low frequencies. Among the tested models, the double-Cole model provided the best interpolation accuracy, while the fractional Hayden models effectively described the temporal evolution of extracellular resistance and membrane-related parameters. Preliminary EIT reconstructions further demonstrate the feasibility of non-destructive tomographic imaging for fruit monitoring. These findings support the potential of EIS and EIT as low-cost, portable, and non-invasive tools for smart food quality assessment and precision agriculture applications.

Electrical Impedance Spectroscopy and Tomography for Fruit Quality Monitoring: A State-of-the-Art Analysis and Experimental Insights / Chiorboli, G., Delmonte, N., Toscani, A.. - In: SENSORS. - ISSN 1424-8220. - 26:13(2026). [10.3390/s26134206]

Electrical Impedance Spectroscopy and Tomography for Fruit Quality Monitoring: A State-of-the-Art Analysis and Experimental Insights

Chiorboli G.;Delmonte N.;Toscani A.
2026-01-01

Abstract

Non-invasive Electrical Impedance Tomography (EIT) and Electrical Impedance Spectroscopy (EIS) are emerging as promising techniques for real-time monitoring and quality assessment in food processing and agri-food applications. This study reviews recent advances in impedance-based sensing for fruit characterization and investigates the experimental implementation of multi-electrode impedance measurements for tomographic imaging. Particular attention is devoted to electrode configurations, electrode polarization effects, and equivalent circuit modeling. Experimental measurements were performed on yellow honeydew melon samples using a four-electrode configuration and a impedance analyzer Keysight E4990 (Keysight Technologies, Santa Rosa, USA) over the frequency range from 20 Hz to 1 MHz. The impedance spectra were validated through Kramers–Kronig consistency tests and interpolated using several fractional-order equivalent circuit models, including single-Cole, double-Cole, and Hayden-based models. The results show that four-electrode measurements are less sensitive to electrode-sample interface artifacts than conventional two-electrode approaches, thereby providing a more reliable estimate of the sample impedance, particularly at low frequencies. Among the tested models, the double-Cole model provided the best interpolation accuracy, while the fractional Hayden models effectively described the temporal evolution of extracellular resistance and membrane-related parameters. Preliminary EIT reconstructions further demonstrate the feasibility of non-destructive tomographic imaging for fruit monitoring. These findings support the potential of EIS and EIT as low-cost, portable, and non-invasive tools for smart food quality assessment and precision agriculture applications.
2026
Electrical Impedance Spectroscopy and Tomography for Fruit Quality Monitoring: A State-of-the-Art Analysis and Experimental Insights / Chiorboli, G., Delmonte, N., Toscani, A.. - In: SENSORS. - ISSN 1424-8220. - 26:13(2026). [10.3390/s26134206]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/3071301
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact