A rapid method for the analysis of dansylated essential and branched-chain amino acids (BCAAs) by micellar electrokinetic capillary chromatography (MECC) is reported. Optimization of analytical conditions has been carried out, evaluating the influence on the performance of several parameters such as sodium dodecyl sulfate (SDS) concentration in the running electrolyte, temperature, and voltage. The effect of the addition of small amounts of isobutanol to the electrolyte has also been investigated. The best separation in the shortest time with a 37 cm capillary was obtained employing a 20 mM Borax buffer (pH 9.1) + 70 mM SDS at 25 °C and 20 kV. Under these conditions a mixture of nine essential amino acids was analyzed in 7 min, while separation of BCAAs occurred in less than 4 min. Using a shorter capillary (20 cm to the detector), the BCAA separation was performed in only 2.5 min. The method was applied to the quantitative analysis of amino acids in three commercial nutraceutical preparations. Assessment of analytical performance in terms of precision, linearity, and limit of detection has also been reported.

Rapid analysis of essential and branched-chain amino acids in nutraceutical products by MEKC / Cavazza, Antonella; Corradini, Claudio; Lauria, A; Stancanelli, R; Nicoletti, I.. - In: JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY. - ISSN 0021-8561. - 48:(2000), pp. 3324-3329. [10.1021/jf991368m]

Rapid analysis of essential and branched-chain amino acids in nutraceutical products by MEKC

CAVAZZA, Antonella;CORRADINI, Claudio;
2000-01-01

Abstract

A rapid method for the analysis of dansylated essential and branched-chain amino acids (BCAAs) by micellar electrokinetic capillary chromatography (MECC) is reported. Optimization of analytical conditions has been carried out, evaluating the influence on the performance of several parameters such as sodium dodecyl sulfate (SDS) concentration in the running electrolyte, temperature, and voltage. The effect of the addition of small amounts of isobutanol to the electrolyte has also been investigated. The best separation in the shortest time with a 37 cm capillary was obtained employing a 20 mM Borax buffer (pH 9.1) + 70 mM SDS at 25 °C and 20 kV. Under these conditions a mixture of nine essential amino acids was analyzed in 7 min, while separation of BCAAs occurred in less than 4 min. Using a shorter capillary (20 cm to the detector), the BCAA separation was performed in only 2.5 min. The method was applied to the quantitative analysis of amino acids in three commercial nutraceutical preparations. Assessment of analytical performance in terms of precision, linearity, and limit of detection has also been reported.
2000
Rapid analysis of essential and branched-chain amino acids in nutraceutical products by MEKC / Cavazza, Antonella; Corradini, Claudio; Lauria, A; Stancanelli, R; Nicoletti, I.. - In: JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY. - ISSN 0021-8561. - 48:(2000), pp. 3324-3329. [10.1021/jf991368m]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2298015
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 12
social impact