This study presents a reliability-oriented power-cycling setup that integrates in-gel GaAs fiber-optic sensing with standard TSEP (Thermal Sensitive Electrical Parameter)-based junction temperature (𝑇j) estimation inside a power cycling test bench PCTB-E-1200-30 for industrial IGBT modules. The GaAs probe (OpSens OTG-PM) is equipped with a retractable ceramic guide to pierce silicone gel and, according to the vendor specifications, achieves ±0.8°C system accuracy with full EMI immunity, thus enabling direct, local 𝑇j sensing during cycling. We apply the method to an Infineon half bridge FF450R12ME4 (EconoDUAL 3, 1200V/450A) and cross-check it against TSEP (measuring 𝑉CE at a constant 𝐼sense) natively supported by the PCTB. Using calibration data, we built an uncertainty budget for the optical channel and obtained an expanded (95%) uncertainty of ≈0.92 °C. Additionally, this study provides initial 𝑍th transients and a two-pole Foster network that establishes a quantitative baseline for future thermal-model validation under modified boundary conditions.
Integrating GaAs optical probes with power cycling: In-gel Tj sensing and Zth monitoring / Santoro, D., Zino, M., Sakib, M.I.I., Bhoi, S.K., Martin, G.E., Cova, P., Delmonte, N., Hegazy, O., Chakraborty, S.. - In: MICROELECTRONIC ENGINEERING. - ISSN 0167-9317. - 308:(2027). [10.1016/j.mee.2026.112528]
Integrating GaAs optical probes with power cycling: In-gel Tj sensing and Zth monitoring
Santoro, D.;Cova, P.
;Delmonte, N.;Chakraborty, S.
2027-01-01
Abstract
This study presents a reliability-oriented power-cycling setup that integrates in-gel GaAs fiber-optic sensing with standard TSEP (Thermal Sensitive Electrical Parameter)-based junction temperature (𝑇j) estimation inside a power cycling test bench PCTB-E-1200-30 for industrial IGBT modules. The GaAs probe (OpSens OTG-PM) is equipped with a retractable ceramic guide to pierce silicone gel and, according to the vendor specifications, achieves ±0.8°C system accuracy with full EMI immunity, thus enabling direct, local 𝑇j sensing during cycling. We apply the method to an Infineon half bridge FF450R12ME4 (EconoDUAL 3, 1200V/450A) and cross-check it against TSEP (measuring 𝑉CE at a constant 𝐼sense) natively supported by the PCTB. Using calibration data, we built an uncertainty budget for the optical channel and obtained an expanded (95%) uncertainty of ≈0.92 °C. Additionally, this study provides initial 𝑍th transients and a two-pole Foster network that establishes a quantitative baseline for future thermal-model validation under modified boundary conditions.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


