Isolated three-port dc-dc converters (TPCs) facilitate integration of three voltage sources/loads in electric vehicle applications. Three-port resonant converter (TPRC) is an attractive TPC topology as it inherits the advantages of resonant converters. Phase-shift (PS) control applied to TPRCs enables independent power flow control among all ports. Phase-shift and duty-ratio (PSDR) control introduces three additional degrees of freedom providing the potential for improving the converter efficiency compared to PS control. This article presents a generalized harmonic approximation-based steady-state mathematical model for a TPRC with five-variable PSDR control. Mathematical solutions to the steady-state converter bridge voltages and the ac currents under PSDR control are provided. The proposed mathematical model is integrated with a TPRC power loss model and together are used to formulate a control optimization problem for evaluating the optimal control variables at maximum converter efficiency. The optimized five-variable PSDR control is compared against PS control using a 6 kW/100 kHz rated hardware demonstrator, with efficiency improvements as high as 12.4%.
Phase-Shift and Duty-Ratio Control Optimization of a 6 kW Three-Port Resonant DC–DC Converter for Dual Auxiliary Voltage EV Applications / Mudiyanselage, Guvanthi Abeysinghe; Pradhan, Rachit; Kozielski, Kyle; Zhou, Linke; Pietrini, Giorgio; Nayak, Parthasarathy; Emadi, Ali. - In: IEEE TRANSACTIONS ON POWER ELECTRONICS. - ISSN 0885-8993. - 39:10(2024), pp. 12774-12793. [10.1109/tpel.2024.3422408]
Phase-Shift and Duty-Ratio Control Optimization of a 6 kW Three-Port Resonant DC–DC Converter for Dual Auxiliary Voltage EV Applications
Pietrini, Giorgio;
2024-01-01
Abstract
Isolated three-port dc-dc converters (TPCs) facilitate integration of three voltage sources/loads in electric vehicle applications. Three-port resonant converter (TPRC) is an attractive TPC topology as it inherits the advantages of resonant converters. Phase-shift (PS) control applied to TPRCs enables independent power flow control among all ports. Phase-shift and duty-ratio (PSDR) control introduces three additional degrees of freedom providing the potential for improving the converter efficiency compared to PS control. This article presents a generalized harmonic approximation-based steady-state mathematical model for a TPRC with five-variable PSDR control. Mathematical solutions to the steady-state converter bridge voltages and the ac currents under PSDR control are provided. The proposed mathematical model is integrated with a TPRC power loss model and together are used to formulate a control optimization problem for evaluating the optimal control variables at maximum converter efficiency. The optimized five-variable PSDR control is compared against PS control using a 6 kW/100 kHz rated hardware demonstrator, with efficiency improvements as high as 12.4%.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


