Purpose This systematic review of randomized-controlled trials (RCTs) with meta-analyses aimed to compare the effects on intraoperative arterial oxygen tension to inspired oxygen fraction ratio (PaO2/FiO2), exerted by positive end-expiratory pressure (PEEP) individualized trough electrical impedance tomography (EIT) or esophageal pressure (Pes) assessment (intervention) vs. PEEP not tailored on EIT or Pes (control), in patients undergoing abdominal or pelvic surgery with an open or laparoscopic/robotic approach.Methods PUBMED (R), EMBASE (R), and Cochrane Controlled Clinical trials register were searched for observational studies and RCTs from inception to the end of August 2022. Inclusion criteria were: RCTs comparing PEEP titrated on EIT/Pes assessment vs. PEEP not individualized on EIT/Pes and reporting intraoperative PaO2/FiO(2). Two authors independently extracted data from the enrolled investigations. Data are reported as mean difference and 95% confidence interval (CI).Results Six RCTs were included for a total of 240 patients undergoing general anesthesia for surgery, of whom 117 subjects in the intervention group and 123 subjects in the control group. The intraoperative mean PaO2/FiO(2) was 69.6 (95%CI 32.-106.4 ) mmHg higher in the intervention group as compared with the control group with 81.4% between-study heterogeneity (p < 0.01). However, at meta-regression, the between-study heterogeneity diminished to 44.96% when data were moderated for body mass index (estimate 3.45, 95%CI 0.78-6.11, p = 0.011).Conclusions In patients undergoing abdominal or pelvic surgery with an open or laparoscopic/robotic approach, PEEP personalized by EIT or Pes allowed the achievement of a better intraoperative oxygenation compared to PEEP not individualized through EIT or Pes.

Intraoperative individualization of positive-end-expiratory pressure through electrical impedance tomography or esophageal pressure assessment: a systematic review and meta-analysis of randomized controlled trials / Esposito, Teresa; Fregonese, Martina; Morettini, Giulio; Carboni, Paloma; Tardioli, Cecilia; Messina, Antonio; Vaschetto, Rosanna; Della Corte, Francesco; Vetrugno, Luigi; Navalesi, Paolo; De Robertis, Edoardo; Azzolina, Danila; Piriyapatsom, Annop; Tucci, Mauro R; Wrigge, Hermann; Simon, Philipp; Bignami, Elena; Maggiore, Salvatore M; Simonte, Rachele; Cammarota, Gianmaria. - In: JOURNAL OF CLINICAL MONITORING AND COMPUTING. - ISSN 1573-2614. - 38:1(2024). [10.1007/s10877-023-01094-2]

Intraoperative individualization of positive-end-expiratory pressure through electrical impedance tomography or esophageal pressure assessment: a systematic review and meta-analysis of randomized controlled trials

Bignami, Elena;
2024-01-01

Abstract

Purpose This systematic review of randomized-controlled trials (RCTs) with meta-analyses aimed to compare the effects on intraoperative arterial oxygen tension to inspired oxygen fraction ratio (PaO2/FiO2), exerted by positive end-expiratory pressure (PEEP) individualized trough electrical impedance tomography (EIT) or esophageal pressure (Pes) assessment (intervention) vs. PEEP not tailored on EIT or Pes (control), in patients undergoing abdominal or pelvic surgery with an open or laparoscopic/robotic approach.Methods PUBMED (R), EMBASE (R), and Cochrane Controlled Clinical trials register were searched for observational studies and RCTs from inception to the end of August 2022. Inclusion criteria were: RCTs comparing PEEP titrated on EIT/Pes assessment vs. PEEP not individualized on EIT/Pes and reporting intraoperative PaO2/FiO(2). Two authors independently extracted data from the enrolled investigations. Data are reported as mean difference and 95% confidence interval (CI).Results Six RCTs were included for a total of 240 patients undergoing general anesthesia for surgery, of whom 117 subjects in the intervention group and 123 subjects in the control group. The intraoperative mean PaO2/FiO(2) was 69.6 (95%CI 32.-106.4 ) mmHg higher in the intervention group as compared with the control group with 81.4% between-study heterogeneity (p < 0.01). However, at meta-regression, the between-study heterogeneity diminished to 44.96% when data were moderated for body mass index (estimate 3.45, 95%CI 0.78-6.11, p = 0.011).Conclusions In patients undergoing abdominal or pelvic surgery with an open or laparoscopic/robotic approach, PEEP personalized by EIT or Pes allowed the achievement of a better intraoperative oxygenation compared to PEEP not individualized through EIT or Pes.
2024
Intraoperative individualization of positive-end-expiratory pressure through electrical impedance tomography or esophageal pressure assessment: a systematic review and meta-analysis of randomized controlled trials / Esposito, Teresa; Fregonese, Martina; Morettini, Giulio; Carboni, Paloma; Tardioli, Cecilia; Messina, Antonio; Vaschetto, Rosanna; Della Corte, Francesco; Vetrugno, Luigi; Navalesi, Paolo; De Robertis, Edoardo; Azzolina, Danila; Piriyapatsom, Annop; Tucci, Mauro R; Wrigge, Hermann; Simon, Philipp; Bignami, Elena; Maggiore, Salvatore M; Simonte, Rachele; Cammarota, Gianmaria. - In: JOURNAL OF CLINICAL MONITORING AND COMPUTING. - ISSN 1573-2614. - 38:1(2024). [10.1007/s10877-023-01094-2]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2994917
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 4
social impact