Aim: To evaluate contrast-enhanced ultrasound (CEUS) as an effective alternative to CT-angiography (CTA) for endoleak detection and aneurismal sac diameter measurement in the follow-up after endovascular abdominal aortic aneurysm repair (EVAR). Methods: From January 2006 to December 2010, 395 patients underwent EVAR follow-up with both CTA and CEUS. The diameter of the aneurismal sac and the presence of endoleaks were evaluated in all the 395 paired examinations. Results: Bland-Altman plots showed a good agreement in aneurismal sac diameter evaluation between the two imaging modalities. The mean diameter was 54.93 mm (standard deviation (SD) ±12.57) with CEUS and 56.01 mm (SD ± 13.23) with CTA. The mean difference in aneurismal sac diameter was -1.08 mm ± 3.3543 (95% confidence interval (CI), -0.75 to -1.41), in favour of CTA. The number of observed agreement in endoleak detection was 359/395 (90.89%). The two modalities detected the same type I and type III endoleaks. McNemar's Ï 2 test confirmed that CTA and CEUS are equivalent in endoleak detection. Conclusions: CEUS demonstrated to be as accurate as CTA in endoleak detection and abdominal aortic aneurysm diameter measurements during EVAR follow-up, without carrying the risks of radiation exposure or nephrotoxicity. Even if it cannot be proposed as the sole imaging modality during follow-up, our analysis suggests that it should have a major role. © 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

Single-centre prospective comparison between contrast-enhanced ultrasound and computed tomography angiography after EVAR / Perini, P.; Sediri, I.; Midulla, M.; Delsart, P.; Mouton, S.; Gautier, C.; Pruvo, J. -P.; Haulon, S.. - In: EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY. - ISSN 1078-5884. - 42:6(2011), pp. 797-802. [10.1016/j.ejvs.2011.09.003]

Single-centre prospective comparison between contrast-enhanced ultrasound and computed tomography angiography after EVAR

Perini, P.;
2011-01-01

Abstract

Aim: To evaluate contrast-enhanced ultrasound (CEUS) as an effective alternative to CT-angiography (CTA) for endoleak detection and aneurismal sac diameter measurement in the follow-up after endovascular abdominal aortic aneurysm repair (EVAR). Methods: From January 2006 to December 2010, 395 patients underwent EVAR follow-up with both CTA and CEUS. The diameter of the aneurismal sac and the presence of endoleaks were evaluated in all the 395 paired examinations. Results: Bland-Altman plots showed a good agreement in aneurismal sac diameter evaluation between the two imaging modalities. The mean diameter was 54.93 mm (standard deviation (SD) ±12.57) with CEUS and 56.01 mm (SD ± 13.23) with CTA. The mean difference in aneurismal sac diameter was -1.08 mm ± 3.3543 (95% confidence interval (CI), -0.75 to -1.41), in favour of CTA. The number of observed agreement in endoleak detection was 359/395 (90.89%). The two modalities detected the same type I and type III endoleaks. McNemar's Ï 2 test confirmed that CTA and CEUS are equivalent in endoleak detection. Conclusions: CEUS demonstrated to be as accurate as CTA in endoleak detection and abdominal aortic aneurysm diameter measurements during EVAR follow-up, without carrying the risks of radiation exposure or nephrotoxicity. Even if it cannot be proposed as the sole imaging modality during follow-up, our analysis suggests that it should have a major role. © 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
2011
Single-centre prospective comparison between contrast-enhanced ultrasound and computed tomography angiography after EVAR / Perini, P.; Sediri, I.; Midulla, M.; Delsart, P.; Mouton, S.; Gautier, C.; Pruvo, J. -P.; Haulon, S.. - In: EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY. - ISSN 1078-5884. - 42:6(2011), pp. 797-802. [10.1016/j.ejvs.2011.09.003]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2961053
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 70
  • ???jsp.display-item.citation.isi??? 66
social impact