Background: There is no gold standard in diagnosing SAD. Indicators of SAD are considered: (a) a value <65% of predicted values of two of three measures, FEF25-75, FEF50 e FEF75 (FEF+); (b) a value of FEV3/FEV6 < LLN (FEV3/FEV6+); (c) an IOS value of R5-R20 >0.07 kPa·s·L-1 (R5-R20+). Aim and objectives: The aim of the study was to ascertain, in asthmatic patients, whether spirometry and IOS indicators agree in detecting SAD. We also assessed the relationship between spirometry and IOS indicators and clinical features of asthma. Methods: We prospectively recruited adult asthmatic patients. Anthropometric and clinical characteristics were recorded. All patients performed spirometry and IOS tests. Results: We enrolled 301 asthmatic patients (179 females; mean age 50 ± 16 years) with normal to moderately severe degree of airway obstruction; 91% were non-smokers, 74% were atopic, 28% had an exacerbation in the previous year, and 18% had a poor asthma control by ACT. SAD was diagnosed in 62% of patients through FEF+, in 40% through FEV3/FEV6+ and in 41% through R5-R20+. κ values were 0.49 between FEF+ and FEV3/FEV6+, 0.20 between FEF+ and R5-R20+, 0.07 between FEV3/FEV6+ and R5-R20+. R5-R20+ but not FEF+ and FEV3/FEV6+ was significantly associated with ACT score (p < 0.05). Conclusions: Our study shows that in mild to moderately severe asthmatic patients, spirometry and IOS indicators are complementary in diagnosing SAD. Additionally, IOS indicator, but not spirometry ones, was related to asthma control.

Detection of Small Airway Dysfunction in Asthmatic Patients by Spirometry and Impulse Oscillometry System / Pisi, Roberta; Aiello, Marina; Frizzelli, Annalisa; Feci, Davide; Aredano, Ilaria; Manari, Gaia; Calzetta, Luigino; Pela', Giovanna Maria; Chetta, Alfredo Antonio. - In: RESPIRATION. - ISSN 1423-0356. - Online ahead of print:(2023). [10.1159/000531205]

Detection of Small Airway Dysfunction in Asthmatic Patients by Spirometry and Impulse Oscillometry System

Roberta Pisi;Marina Aiello;Annalisa Frizzelli;Davide Feci;Ilaria Aredano;Gaia Manari;Luigino Calzetta;Giovanna Pela';Alfredo Chetta
2023-01-01

Abstract

Background: There is no gold standard in diagnosing SAD. Indicators of SAD are considered: (a) a value <65% of predicted values of two of three measures, FEF25-75, FEF50 e FEF75 (FEF+); (b) a value of FEV3/FEV6 < LLN (FEV3/FEV6+); (c) an IOS value of R5-R20 >0.07 kPa·s·L-1 (R5-R20+). Aim and objectives: The aim of the study was to ascertain, in asthmatic patients, whether spirometry and IOS indicators agree in detecting SAD. We also assessed the relationship between spirometry and IOS indicators and clinical features of asthma. Methods: We prospectively recruited adult asthmatic patients. Anthropometric and clinical characteristics were recorded. All patients performed spirometry and IOS tests. Results: We enrolled 301 asthmatic patients (179 females; mean age 50 ± 16 years) with normal to moderately severe degree of airway obstruction; 91% were non-smokers, 74% were atopic, 28% had an exacerbation in the previous year, and 18% had a poor asthma control by ACT. SAD was diagnosed in 62% of patients through FEF+, in 40% through FEV3/FEV6+ and in 41% through R5-R20+. κ values were 0.49 between FEF+ and FEV3/FEV6+, 0.20 between FEF+ and R5-R20+, 0.07 between FEV3/FEV6+ and R5-R20+. R5-R20+ but not FEF+ and FEV3/FEV6+ was significantly associated with ACT score (p < 0.05). Conclusions: Our study shows that in mild to moderately severe asthmatic patients, spirometry and IOS indicators are complementary in diagnosing SAD. Additionally, IOS indicator, but not spirometry ones, was related to asthma control.
2023
Detection of Small Airway Dysfunction in Asthmatic Patients by Spirometry and Impulse Oscillometry System / Pisi, Roberta; Aiello, Marina; Frizzelli, Annalisa; Feci, Davide; Aredano, Ilaria; Manari, Gaia; Calzetta, Luigino; Pela', Giovanna Maria; Chetta, Alfredo Antonio. - In: RESPIRATION. - ISSN 1423-0356. - Online ahead of print:(2023). [10.1159/000531205]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2955614
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact