Background Intracoronary physiologic indexes such as coronary flow reserve (CFR) and left ventricular ejection fraction (LVEF) have been regarded as prognostic indicators in patients with coronary artery disease. The current study evaluated the association between intracoronary physiologic indexes and LVEF and their differential prognostic implications in patients with coronary artery disease. Methods and Results A total of 1889 patients with 2492 vessels with available CFR and LVEF were selected from an international multicenter prospective registry. Baseline physiologic indexes were measured by thermodilution or Doppler methods and LVEF was recorded at the index procedure. The primary outcome was target vessel failure, which was a composite of cardiac death, target vessel myocardial infarction, or clinically driven target vessel revascularization over 5 years of follow-up. Patients with reduced LVEF <50% (162 patients [8.6%], 202 vessels [8.1%]) showed a similar degree of epicardial coronary artery disease but lower CFR values than those with preserved LVEF (2.4±1.2 versus 2.7±1.2, P<0.001), mainly driven by the increased resting coronary flow. Conversely, hyperemic coronary flow, fractional flow reserve, and the degree of microvascular dysfunction were similar between the 2 groups. Reduced CFR (≤2.0) was seen in 613 patients (32.5%) with 771 vessels (30.9%). Reduced CFR was an independent predictor for target vessel failure (hazard ratio, 2.081 [95% CI, 1.385-3.126], P<0.001), regardless of LVEF. Conclusions CFR was lower in patients with reduced LVEF because of increased resting coronary flow. Patients with reduced CFR showed a significantly higher risk of target vessel failure than did those with preserved CFR, regardless of LVEF. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT04485234.

Prognostic Impact of Coronary Flow Reserve in Patients With Reduced Left Ventricular Ejection Fraction / Joh, Hyun Sung; Shin, Doosup; Lee, Joo Myung; Lee, Seung Hun; Hong, David; Choi, Ki Hong; Hwang, Doyeon; Boerhout, Coen K M; de Waard, Guus A; Jung, Ji-Hyun; Mejia-Renteria, Hernan; Hoshino, Masahiro; Echavarria-Pinto, Mauro; Meuwissen, Martijn; Matsuo, Hitoshi; Madera-Cambero, Maribel; Eftekhari, Ashkan; Effat, Mohamed A; Murai, Tadashi; Marques, Koen; Doh, Joon-Hyung; Christiansen, Evald H; Banerjee, Rupak; Kim, Hyun Kuk; Nam, Chang-Wook; Niccoli, Giampaolo; Nakayama, Masafumi; Tanaka, Nobuhiro; Shin, Eun-Seok; Chamuleau, Steven A J; van Royen, Niels; Knaapen, Paul; Koo, Bon Kwon; Kakuta, Tsunekazu; Escaned, Javier; Piek, Jan J; van de Hoef, Tim P. - In: JOURNAL OF THE AMERICAN HEART ASSOCIATION. CARDIOVASCULAR AND CEREBROVASCULAR DISEASE. - ISSN 2047-9980. - 11:15(2022). [10.1161/JAHA.122.025841]

Prognostic Impact of Coronary Flow Reserve in Patients With Reduced Left Ventricular Ejection Fraction

Niccoli, Giampaolo;
2022-01-01

Abstract

Background Intracoronary physiologic indexes such as coronary flow reserve (CFR) and left ventricular ejection fraction (LVEF) have been regarded as prognostic indicators in patients with coronary artery disease. The current study evaluated the association between intracoronary physiologic indexes and LVEF and their differential prognostic implications in patients with coronary artery disease. Methods and Results A total of 1889 patients with 2492 vessels with available CFR and LVEF were selected from an international multicenter prospective registry. Baseline physiologic indexes were measured by thermodilution or Doppler methods and LVEF was recorded at the index procedure. The primary outcome was target vessel failure, which was a composite of cardiac death, target vessel myocardial infarction, or clinically driven target vessel revascularization over 5 years of follow-up. Patients with reduced LVEF <50% (162 patients [8.6%], 202 vessels [8.1%]) showed a similar degree of epicardial coronary artery disease but lower CFR values than those with preserved LVEF (2.4±1.2 versus 2.7±1.2, P<0.001), mainly driven by the increased resting coronary flow. Conversely, hyperemic coronary flow, fractional flow reserve, and the degree of microvascular dysfunction were similar between the 2 groups. Reduced CFR (≤2.0) was seen in 613 patients (32.5%) with 771 vessels (30.9%). Reduced CFR was an independent predictor for target vessel failure (hazard ratio, 2.081 [95% CI, 1.385-3.126], P<0.001), regardless of LVEF. Conclusions CFR was lower in patients with reduced LVEF because of increased resting coronary flow. Patients with reduced CFR showed a significantly higher risk of target vessel failure than did those with preserved CFR, regardless of LVEF. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT04485234.
2022
Prognostic Impact of Coronary Flow Reserve in Patients With Reduced Left Ventricular Ejection Fraction / Joh, Hyun Sung; Shin, Doosup; Lee, Joo Myung; Lee, Seung Hun; Hong, David; Choi, Ki Hong; Hwang, Doyeon; Boerhout, Coen K M; de Waard, Guus A; Jung, Ji-Hyun; Mejia-Renteria, Hernan; Hoshino, Masahiro; Echavarria-Pinto, Mauro; Meuwissen, Martijn; Matsuo, Hitoshi; Madera-Cambero, Maribel; Eftekhari, Ashkan; Effat, Mohamed A; Murai, Tadashi; Marques, Koen; Doh, Joon-Hyung; Christiansen, Evald H; Banerjee, Rupak; Kim, Hyun Kuk; Nam, Chang-Wook; Niccoli, Giampaolo; Nakayama, Masafumi; Tanaka, Nobuhiro; Shin, Eun-Seok; Chamuleau, Steven A J; van Royen, Niels; Knaapen, Paul; Koo, Bon Kwon; Kakuta, Tsunekazu; Escaned, Javier; Piek, Jan J; van de Hoef, Tim P. - In: JOURNAL OF THE AMERICAN HEART ASSOCIATION. CARDIOVASCULAR AND CEREBROVASCULAR DISEASE. - ISSN 2047-9980. - 11:15(2022). [10.1161/JAHA.122.025841]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2933425
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2
social impact