We present organic near-infrared photodetectors based on the absorption of charge-transfer (CT) states at the zinc-phthalocyanine–C60 interface. By using a resonant optical cavity device architecture, we achieve a narrowband detection, centered around 1060 nm and well below (>200 nm) the optical gap of the neat materials. We measure transient photocurrent responses at wavelengths of 532 and 1064 nm, exciting dominantly the neat materials or the CT state, respectively, and obtain rise and fall times of a few nanoseconds at short circuit, independent of the excitation wavelength. The current transients are modeled with time-dependent drift-diffusion simulations of electrons and holes which reconstruct the photocurrent signal, including capacitance and series resistance effects. The hole mobility of the donor material is identified as the limiting factor for the high-frequency response. With this knowledge, we demonstrate a new device concept, which balances hole and electron extraction times and achieves a cutoff frequency of 68 MHz upon 1064 nm CT excitation.

Fast Organic Near-Infrared Photodetectors Based on Charge-Transfer Absorption / Ullbrich, S; Siegmund, B; Mischok, A; Hofacker, A; Benduhn, J; Spoltore, D; Vandewal, K. - In: THE JOURNAL OF PHYSICAL CHEMISTRY LETTERS. - ISSN 1948-7185. - 8:(2017), pp. 5621-5625. [10.1021/acs.jpclett.7b02571]

Fast Organic Near-Infrared Photodetectors Based on Charge-Transfer Absorption

Spoltore D;
2017-01-01

Abstract

We present organic near-infrared photodetectors based on the absorption of charge-transfer (CT) states at the zinc-phthalocyanine–C60 interface. By using a resonant optical cavity device architecture, we achieve a narrowband detection, centered around 1060 nm and well below (>200 nm) the optical gap of the neat materials. We measure transient photocurrent responses at wavelengths of 532 and 1064 nm, exciting dominantly the neat materials or the CT state, respectively, and obtain rise and fall times of a few nanoseconds at short circuit, independent of the excitation wavelength. The current transients are modeled with time-dependent drift-diffusion simulations of electrons and holes which reconstruct the photocurrent signal, including capacitance and series resistance effects. The hole mobility of the donor material is identified as the limiting factor for the high-frequency response. With this knowledge, we demonstrate a new device concept, which balances hole and electron extraction times and achieves a cutoff frequency of 68 MHz upon 1064 nm CT excitation.
2017
Fast Organic Near-Infrared Photodetectors Based on Charge-Transfer Absorption / Ullbrich, S; Siegmund, B; Mischok, A; Hofacker, A; Benduhn, J; Spoltore, D; Vandewal, K. - In: THE JOURNAL OF PHYSICAL CHEMISTRY LETTERS. - ISSN 1948-7185. - 8:(2017), pp. 5621-5625. [10.1021/acs.jpclett.7b02571]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2918462
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 39
  • ???jsp.display-item.citation.isi??? 41
social impact