In the last decades, many alleviation measures were proposed in order to improve the life of fretting fatigue-affected components. In such a context, the shot peening treatment is worth noting. Therefore, in the present paper, the fatigue life of shot-peened aluminium and titanium alloy specimens, subject to fretting fatigue under partial slip regime, is assessed by means of the Carpinteri et al. criterion for fretting fatigue. First, according to the superposition principle, the relaxed residual stresses (due to the shot peening treatment) are combined with the stress components due to fretting fatigue loading. Then fretting fatigue assessment is performed. In such a context, a novel theoretical law for the relaxed residual stress field is here proposed, the implementation of which shows very promising results in terms of fretting fatigue life estimation of the shot-peened specimens examined.
Fretting-fatigue analysis of shot-peened aluminium and titanium test specimens / Vantadori, S.; Zanichelli, A.. - In: FATIGUE & FRACTURE OF ENGINEERING MATERIALS & STRUCTURES. - ISSN 8756-758X. - (2020). [10.1111/ffe.13367]
Fretting-fatigue analysis of shot-peened aluminium and titanium test specimens
Vantadori S.;Zanichelli A.
2020-01-01
Abstract
In the last decades, many alleviation measures were proposed in order to improve the life of fretting fatigue-affected components. In such a context, the shot peening treatment is worth noting. Therefore, in the present paper, the fatigue life of shot-peened aluminium and titanium alloy specimens, subject to fretting fatigue under partial slip regime, is assessed by means of the Carpinteri et al. criterion for fretting fatigue. First, according to the superposition principle, the relaxed residual stresses (due to the shot peening treatment) are combined with the stress components due to fretting fatigue loading. Then fretting fatigue assessment is performed. In such a context, a novel theoretical law for the relaxed residual stress field is here proposed, the implementation of which shows very promising results in terms of fretting fatigue life estimation of the shot-peened specimens examined.File | Dimensione | Formato | |
---|---|---|---|
Allegato 5.1.103.pdf
solo utenti autorizzati
Descrizione: Full text
Tipologia:
Versione (PDF) editoriale
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
1.76 MB
Formato
Adobe PDF
|
1.76 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Fretting-fatigue.pdf
accesso aperto
Tipologia:
Documento in Post-print
Licenza:
Creative commons
Dimensione
539.13 kB
Formato
Adobe PDF
|
539.13 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.