Objectives This study sought to evaluate the diagnostic accuracy of 64-slice multislice computed tomography (MSCT) coronary angiography in the follow-up of patients with previous coronary stent implantation. Background Recent investigations have shown increased image quality and diagnostic accuracy for noninvasive coronary angiography with 64-slice MSCT as compared with previous-generation MSCT scanners, but data on the evaluation of coronary stents are scarce. Methods In 182 patients (152 [84%] male, ages 58 +/- 11 years) with previous stent (>= 2.5 mm diameter) implantation (n = 192), 64-slice MSCT angiography using either a Sensation 64 (Siemens, Forchheim, Germany) or Aquilion 64 (Toshiba, Otawara, Japan) was performed. At each center, coronary stents were evaluated by 2 experienced observers and evaluated for the presence of significant (>= 50%) in-stent restenosis. Quantitative coronary angiography served as the standard of reference. Results A total of 14 (7.3%) stented segments were excluded because of poor image quality. In the interpretable stents, 20 of the 178 (11.2%) evaluated stents were significantly diseased, of which 19 were correctly detected by 64-slice MSCT. Accordingly, sensitivity, specificity, and positive and negative predictive value to identify in-stent restenosis in interpretable stents were 95.0% (95% confidence interval [CI] 85% to 100%), 93.0% (95% CI 90% to 97%), 63.3% (95% CI 46% to 81%), and 99.3% (95% CI 98% to 100%), respectively. Conclusions In-stent restenosis can be evaluated with 64-slice MSCT with good diagnostic accuracy. In particular, a high negative predictive value of 99% was observed, indicating that 64-slice MSCT may be most valuable as a noninvasive method of excluding in-stent restenosis.

Usefulness of 64-slice multislice computed tomography coronary angiography to assess in-stent restenosis / Cademartiri, F., Schuijf Joanne, D., Pugliese, F., Mollet Nico, R., Jukema J., W., Maffiel, E., Kroft Lucia, J., Palumbo, A., Ardissino, D., Serruys Patrick, W., Krestin Gabriel, P., Van der Wall Ernst, E., de Feyter Pim, J., Bax Jeroen, J.. - In: JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY. - ISSN 0735-1097. - 49:22(2007), pp. 2204-2210. [10.1016/j.jacc.2007.02.045]

Usefulness of 64-slice multislice computed tomography coronary angiography to assess in-stent restenosis

Ardissino D;
2007-01-01

Abstract

Objectives This study sought to evaluate the diagnostic accuracy of 64-slice multislice computed tomography (MSCT) coronary angiography in the follow-up of patients with previous coronary stent implantation. Background Recent investigations have shown increased image quality and diagnostic accuracy for noninvasive coronary angiography with 64-slice MSCT as compared with previous-generation MSCT scanners, but data on the evaluation of coronary stents are scarce. Methods In 182 patients (152 [84%] male, ages 58 +/- 11 years) with previous stent (>= 2.5 mm diameter) implantation (n = 192), 64-slice MSCT angiography using either a Sensation 64 (Siemens, Forchheim, Germany) or Aquilion 64 (Toshiba, Otawara, Japan) was performed. At each center, coronary stents were evaluated by 2 experienced observers and evaluated for the presence of significant (>= 50%) in-stent restenosis. Quantitative coronary angiography served as the standard of reference. Results A total of 14 (7.3%) stented segments were excluded because of poor image quality. In the interpretable stents, 20 of the 178 (11.2%) evaluated stents were significantly diseased, of which 19 were correctly detected by 64-slice MSCT. Accordingly, sensitivity, specificity, and positive and negative predictive value to identify in-stent restenosis in interpretable stents were 95.0% (95% confidence interval [CI] 85% to 100%), 93.0% (95% CI 90% to 97%), 63.3% (95% CI 46% to 81%), and 99.3% (95% CI 98% to 100%), respectively. Conclusions In-stent restenosis can be evaluated with 64-slice MSCT with good diagnostic accuracy. In particular, a high negative predictive value of 99% was observed, indicating that 64-slice MSCT may be most valuable as a noninvasive method of excluding in-stent restenosis.
2007
Usefulness of 64-slice multislice computed tomography coronary angiography to assess in-stent restenosis / Cademartiri, F., Schuijf Joanne, D., Pugliese, F., Mollet Nico, R., Jukema J., W., Maffiel, E., Kroft Lucia, J., Palumbo, A., Ardissino, D., Serruys Patrick, W., Krestin Gabriel, P., Van der Wall Ernst, E., de Feyter Pim, J., Bax Jeroen, J.. - In: JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY. - ISSN 0735-1097. - 49:22(2007), pp. 2204-2210. [10.1016/j.jacc.2007.02.045]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2883749
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 152
  • ???jsp.display-item.citation.isi??? 109
social impact