Background: Three millimeter is considered as the minimum distance to obtain soft and bone tissue stability in case of adjacent implants. The possibility to preserve peri-implant bone level using a platform switching connection has questioned this concept. Purpose: The study evaluates soft tissue maintenance and marginal bone stability around implants, placed at 2 or 3 mm of distance. Materials and methods: Thirty patients received two immediately loaded implants either at 2-mm (test) or at 3-mm (control) of distance in the premolar area. Soft tissue esthetics (papilla height and fill, keratinized tissue, recession) and radiographic peri-implant bone level changes were measured at 3, 6, and 12 months. Results: No significant differences between the two groups were detected neither for all soft tissue esthetic outcomes nor for bone level modifications up to 12 months. Conclusion: The results suggested that up to 12 months post-loading, both 2- and 3-mm inter-distance platform-switched implants in healed site, supported adequate esthetic outcomes and peri-implant bone stability.

The effect of a 2-mm inter-implant distance on esthetic outcomes in immediately non-occlusally loaded platform shifted implants in healed ridges: 12-month results of a randomized clinical trial / Rivara, Federico; Macaluso, Guido Maria; Toffoli, Andrea; Calciolari, Elena; Goldoni, Matteo; Lumetti, Simone. - In: CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH. - ISSN 1523-0899. - 22:4(2020), pp. 486-496. [10.1111/cid.12926]

The effect of a 2-mm inter-implant distance on esthetic outcomes in immediately non-occlusally loaded platform shifted implants in healed ridges: 12-month results of a randomized clinical trial

Rivara, Federico
;
Macaluso, Guido Maria;Toffoli, Andrea;Calciolari, Elena;Goldoni, Matteo;Lumetti, Simone
2020-01-01

Abstract

Background: Three millimeter is considered as the minimum distance to obtain soft and bone tissue stability in case of adjacent implants. The possibility to preserve peri-implant bone level using a platform switching connection has questioned this concept. Purpose: The study evaluates soft tissue maintenance and marginal bone stability around implants, placed at 2 or 3 mm of distance. Materials and methods: Thirty patients received two immediately loaded implants either at 2-mm (test) or at 3-mm (control) of distance in the premolar area. Soft tissue esthetics (papilla height and fill, keratinized tissue, recession) and radiographic peri-implant bone level changes were measured at 3, 6, and 12 months. Results: No significant differences between the two groups were detected neither for all soft tissue esthetic outcomes nor for bone level modifications up to 12 months. Conclusion: The results suggested that up to 12 months post-loading, both 2- and 3-mm inter-distance platform-switched implants in healed site, supported adequate esthetic outcomes and peri-implant bone stability.
2020
The effect of a 2-mm inter-implant distance on esthetic outcomes in immediately non-occlusally loaded platform shifted implants in healed ridges: 12-month results of a randomized clinical trial / Rivara, Federico; Macaluso, Guido Maria; Toffoli, Andrea; Calciolari, Elena; Goldoni, Matteo; Lumetti, Simone. - In: CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH. - ISSN 1523-0899. - 22:4(2020), pp. 486-496. [10.1111/cid.12926]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2878660
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 9
social impact