In this study, 185 nasopharyngeal swabs were tested to compare the sensitivity and specificity of the Luminex NxTAG (NxTAG) Respiratory Pathogen Panel (RPP) Assay with those of the Luminex Respiratory Virus Panel (RVP) Fast Assay v2 and singleplex real-time polymerase chain reaction (PCR). The NxTAG Assay identified at least one infectious agent in 164 (88.7%) of the swabs. In 91 (6.2%) tests with negative results with the RVP Fast Assay v2, a virus was identified by the NxTAG (P < 0.001). With the NxTAG Assay, the detection rates were significantly higher for respiratory syncytial virus (P = 0.003), human metapneumovirus (P < 0.001), human rhinovirus/human enterovirus (P = 0.009) and human adenovirus (P < 0.001). Finally, the NxTAG Assay identified M. pneumoniae in 32 of 44 (72.7%) PCR-positive samples. However, the concordance with real-time PCR results was low for both assays. In conclusion, the results indicate that the NxTAG Assay overcomes some of the limitations of previous Luminex assays, although further studies are needed for a more complete evaluation of the new assay.

Partial comparison of the NxTAG Respiratory Pathogen Panel Assay with the Luminex xTAG Respiratory Panel Fast Assay V2 and singleplex real-time polymerase chain reaction for detection of respiratory pathogens / Esposito, S.; Scala, A.; Bianchini, S.; Presicce, M. L.; Mori, A.; Sciarrabba, C. S.; Fior, G.; Principi, N.. - In: DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE. - ISSN 0732-8893. - 86:1(2016), pp. 53-57. [10.1016/j.diagmicrobio.2016.06.018]

Partial comparison of the NxTAG Respiratory Pathogen Panel Assay with the Luminex xTAG Respiratory Panel Fast Assay V2 and singleplex real-time polymerase chain reaction for detection of respiratory pathogens

S. Esposito;
2016-01-01

Abstract

In this study, 185 nasopharyngeal swabs were tested to compare the sensitivity and specificity of the Luminex NxTAG (NxTAG) Respiratory Pathogen Panel (RPP) Assay with those of the Luminex Respiratory Virus Panel (RVP) Fast Assay v2 and singleplex real-time polymerase chain reaction (PCR). The NxTAG Assay identified at least one infectious agent in 164 (88.7%) of the swabs. In 91 (6.2%) tests with negative results with the RVP Fast Assay v2, a virus was identified by the NxTAG (P < 0.001). With the NxTAG Assay, the detection rates were significantly higher for respiratory syncytial virus (P = 0.003), human metapneumovirus (P < 0.001), human rhinovirus/human enterovirus (P = 0.009) and human adenovirus (P < 0.001). Finally, the NxTAG Assay identified M. pneumoniae in 32 of 44 (72.7%) PCR-positive samples. However, the concordance with real-time PCR results was low for both assays. In conclusion, the results indicate that the NxTAG Assay overcomes some of the limitations of previous Luminex assays, although further studies are needed for a more complete evaluation of the new assay.
2016
Partial comparison of the NxTAG Respiratory Pathogen Panel Assay with the Luminex xTAG Respiratory Panel Fast Assay V2 and singleplex real-time polymerase chain reaction for detection of respiratory pathogens / Esposito, S.; Scala, A.; Bianchini, S.; Presicce, M. L.; Mori, A.; Sciarrabba, C. S.; Fior, G.; Principi, N.. - In: DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE. - ISSN 0732-8893. - 86:1(2016), pp. 53-57. [10.1016/j.diagmicrobio.2016.06.018]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2864528
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 13
social impact