Psoriasis is a widespread chronic disease affecting 2–4% of the population in Western countries. Its mild-to-moderate form, representing approximately 80% of the total cases, is treated by topical application, with corticosteroid being the standard treatment. However, in case of psoriasis, no single treatment works for every patient and optimizing topical therapy is a key aspect. A possible alternative is represented by cyclosporine, an immunosuppressant cyclic peptide administered orally in the treatment of the severe form. Its topical application could avoid the problems related to systemic immunosuppression, but the unfavourable physico-chemical properties (MW: 1202 Da; LogP ≈ 3) hinder its permeation across the stratum corneum. The aim of the paper was the preparation, characterization and ex-vivo evaluation of cyclosporine loaded microemulsions using oleic acid as oil phase, either Tween®80 or a soluble derivative of vitamin E (TPGS) as surfactants and either Transcutol®, propylene glycol or 1,3 propanediol as co-surfactants. The issue of formulation viscosity was also addressed 1) by evaluating the thickening of Tween®80-based microemulsions by direct addition of different rheological modifiers, 2) by building pseudo-ternary phase diagrams using TPGS, to identify the water/oil/surfactants proportions resulting in viscous self-gelifying systems. Nine formulations (five Tween®80-based and four TPGS-based) were selected, characterized in terms of droplets size (low viscosity systems) or rheological properties (high viscosity systems), loaded with 6 mg/g cyclosporine and applied ex-vivo on porcine skin for 22 h. A relevant skin accumulation was obtained either with a low-viscosity Tween®80-based microemulsion (9.78 ± 3.86 µg/cm2), or with a high viscosity TPGS-based microemulsion (18.3 ± 5.69 µg/cm2), with an increase of about 3 and 6 times respectively for comparison with a control cyclosporine solution in propylene glycol. The role of water content, surfactant, co-surfactant and viscosity was also addressed and discussed. The kinetic of skin uptake from the best performing formulation was finally evaluated, highlighting a relatively quick skin uptake and the achievement, after 2 h of contact, of potentially therapeutic cyclosporine skin concentrations.

Development of microemulsions of suitable viscosity for cyclosporine skin delivery / Benigni, Marta; Pescina, Silvia; Grimaudo, Maria Aurora; Padula, Cristina; Santi, Patrizia; Nicoli, Sara. - In: INTERNATIONAL JOURNAL OF PHARMACEUTICS. - ISSN 0378-5173. - 545:1-2(2018), pp. 197-205. [10.1016/j.ijpharm.2018.04.049]

Development of microemulsions of suitable viscosity for cyclosporine skin delivery

BENIGNI, MARTA;Pescina, Silvia;Grimaudo, Maria Aurora;Padula, Cristina;Santi, Patrizia;Nicoli, Sara
2018-01-01

Abstract

Psoriasis is a widespread chronic disease affecting 2–4% of the population in Western countries. Its mild-to-moderate form, representing approximately 80% of the total cases, is treated by topical application, with corticosteroid being the standard treatment. However, in case of psoriasis, no single treatment works for every patient and optimizing topical therapy is a key aspect. A possible alternative is represented by cyclosporine, an immunosuppressant cyclic peptide administered orally in the treatment of the severe form. Its topical application could avoid the problems related to systemic immunosuppression, but the unfavourable physico-chemical properties (MW: 1202 Da; LogP ≈ 3) hinder its permeation across the stratum corneum. The aim of the paper was the preparation, characterization and ex-vivo evaluation of cyclosporine loaded microemulsions using oleic acid as oil phase, either Tween®80 or a soluble derivative of vitamin E (TPGS) as surfactants and either Transcutol®, propylene glycol or 1,3 propanediol as co-surfactants. The issue of formulation viscosity was also addressed 1) by evaluating the thickening of Tween®80-based microemulsions by direct addition of different rheological modifiers, 2) by building pseudo-ternary phase diagrams using TPGS, to identify the water/oil/surfactants proportions resulting in viscous self-gelifying systems. Nine formulations (five Tween®80-based and four TPGS-based) were selected, characterized in terms of droplets size (low viscosity systems) or rheological properties (high viscosity systems), loaded with 6 mg/g cyclosporine and applied ex-vivo on porcine skin for 22 h. A relevant skin accumulation was obtained either with a low-viscosity Tween®80-based microemulsion (9.78 ± 3.86 µg/cm2), or with a high viscosity TPGS-based microemulsion (18.3 ± 5.69 µg/cm2), with an increase of about 3 and 6 times respectively for comparison with a control cyclosporine solution in propylene glycol. The role of water content, surfactant, co-surfactant and viscosity was also addressed and discussed. The kinetic of skin uptake from the best performing formulation was finally evaluated, highlighting a relatively quick skin uptake and the achievement, after 2 h of contact, of potentially therapeutic cyclosporine skin concentrations.
2018
Development of microemulsions of suitable viscosity for cyclosporine skin delivery / Benigni, Marta; Pescina, Silvia; Grimaudo, Maria Aurora; Padula, Cristina; Santi, Patrizia; Nicoli, Sara. - In: INTERNATIONAL JOURNAL OF PHARMACEUTICS. - ISSN 0378-5173. - 545:1-2(2018), pp. 197-205. [10.1016/j.ijpharm.2018.04.049]
File in questo prodotto:
File Dimensione Formato  
ciclosp skin iris.pdf

accesso aperto

Tipologia: Documento in Post-print
Licenza: Creative commons
Dimensione 1.96 MB
Formato Adobe PDF
1.96 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2849213
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 55
  • ???jsp.display-item.citation.isi??? 48
social impact