We performed an observational longitudinal cohort study on patients affected by stress urinary incontinence (SUI) and surgically treated with a transobturator adjustable tape sling (TOA) in order to evaluate this surgical procedure in terms of efficacy, safety, quality of life (QoL) improvement, and patient satisfaction. For all patients, we recorded: general features, preoperative SUI risk factors, obstetrics history, preoperative urodynamic tests, intraoperative/postoperative complications, number of postoperative sling regulations, postmicturition residue, and hospital stay. All patients were asked to complete the validated short version of the Urogenital Distress Inventory (UDI-6) questionnaire 18 months after discharge to evaluate the efficacy of the TOA system. We added 2 adjunctive items to the UDI-6 in order to evaluate patient satisfaction and QoL. All 77 surgical procedures were performed under locoregional anesthesia without complications. Postoperative TOA regulations were performed in 46.8% of patients immediately after the procedure and in 14.3% during hospitalization. Before discharge, postmicturition residue was negative in 67 cases and less than 50 cc in 10 cases. Mean hospital stay was 2.18 days. From the questionnaire evaluation, we found that after the procedure, 90.9% of patients showed a complete regression of urinary symptoms, 1.3% obtained considerable relief from preoperative symptoms, and 6.6% reported poor or absent symptom improvements; 75.3% of patients were totally satisfied and 5.2% totally disappointed. The possibility of modulating postoperative sling tension and reusing the surgical materials in association with short hospitalization as well as high patient satisfaction render TOA a safe, effective, and low-cost technique for the treatment of female SUI.

Female stress urinary incontinence: Clinical efficacy and satisfaction after transobturator adjustable tape sling. an observational longitudinal cohort study / Patrelli, Tito Silvio; Gizzo, Salvatore; Noventa, Marco; Dall'Asta, Andrea; Musaro', Andrea; Faioli, Raffaele; Zanni, Giuliano Carlo; Piantelli, Giovanni; Lukanovic, Adolf; Bacchi Modena, Alberto; Berretta, Roberto. - In: SURGICAL INNOVATION. - ISSN 1553-3506. - 22:2(2015), pp. 137-142. [10.1177/1553350614535855]

Female stress urinary incontinence: Clinical efficacy and satisfaction after transobturator adjustable tape sling. an observational longitudinal cohort study

Patrelli, Tito Silvio;Dall'Asta, Andrea;MUSARO', Andrea;Faioli, Raffaele;Piantelli, Giovanni;Bacchi Modena, Alberto;Berretta, Roberto
2015-01-01

Abstract

We performed an observational longitudinal cohort study on patients affected by stress urinary incontinence (SUI) and surgically treated with a transobturator adjustable tape sling (TOA) in order to evaluate this surgical procedure in terms of efficacy, safety, quality of life (QoL) improvement, and patient satisfaction. For all patients, we recorded: general features, preoperative SUI risk factors, obstetrics history, preoperative urodynamic tests, intraoperative/postoperative complications, number of postoperative sling regulations, postmicturition residue, and hospital stay. All patients were asked to complete the validated short version of the Urogenital Distress Inventory (UDI-6) questionnaire 18 months after discharge to evaluate the efficacy of the TOA system. We added 2 adjunctive items to the UDI-6 in order to evaluate patient satisfaction and QoL. All 77 surgical procedures were performed under locoregional anesthesia without complications. Postoperative TOA regulations were performed in 46.8% of patients immediately after the procedure and in 14.3% during hospitalization. Before discharge, postmicturition residue was negative in 67 cases and less than 50 cc in 10 cases. Mean hospital stay was 2.18 days. From the questionnaire evaluation, we found that after the procedure, 90.9% of patients showed a complete regression of urinary symptoms, 1.3% obtained considerable relief from preoperative symptoms, and 6.6% reported poor or absent symptom improvements; 75.3% of patients were totally satisfied and 5.2% totally disappointed. The possibility of modulating postoperative sling tension and reusing the surgical materials in association with short hospitalization as well as high patient satisfaction render TOA a safe, effective, and low-cost technique for the treatment of female SUI.
2015
Female stress urinary incontinence: Clinical efficacy and satisfaction after transobturator adjustable tape sling. an observational longitudinal cohort study / Patrelli, Tito Silvio; Gizzo, Salvatore; Noventa, Marco; Dall'Asta, Andrea; Musaro', Andrea; Faioli, Raffaele; Zanni, Giuliano Carlo; Piantelli, Giovanni; Lukanovic, Adolf; Bacchi Modena, Alberto; Berretta, Roberto. - In: SURGICAL INNOVATION. - ISSN 1553-3506. - 22:2(2015), pp. 137-142. [10.1177/1553350614535855]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2841509
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact