This work aims at simulating a retort sterilization process of flexible packaging, performed in autoclave. ANSYS CFD software has been used in this study to simulate the heat transfer inside the retort chamber. Flexible packaging filled with a pumpkin soup has been modelled. Three-dimensional (3D) geometrical configuration of the equipment has been designed and then simulated to evaluate the sterilization level achieved by each packaging inside the retort chamber. In particular, the internal temperature of the product situated in the cold spot of the chamber has been monitored during 5 min of the process (after reaching 85°C inside the product) in order to monitor the time/temperature trend. Experimental tests have been finally performed to validate the simulation model of heat exchange. The sterilization process takes place in a retort chamber by means of "overheated water sprayed" at 403 K and a pressure of 5 atm. Results show a good agreement between the simulated results and the real retort process and confirm the potential value of the simulation model to evaluate the process performance.

Three-dimensional cfd simulation of a "steam water spray" retort process for food vegetable products / Mosna, David; Vignali, Giuseppe. - In: INTERNATIONAL JOURNAL OF FOOD ENGINEERING. - ISSN 1556-3758. - 11:6(2015), pp. 715-729. [10.1515/ijfe-2015-0062]

Three-dimensional cfd simulation of a "steam water spray" retort process for food vegetable products

MOSNA, DAVID;VIGNALI, Giuseppe
2015-01-01

Abstract

This work aims at simulating a retort sterilization process of flexible packaging, performed in autoclave. ANSYS CFD software has been used in this study to simulate the heat transfer inside the retort chamber. Flexible packaging filled with a pumpkin soup has been modelled. Three-dimensional (3D) geometrical configuration of the equipment has been designed and then simulated to evaluate the sterilization level achieved by each packaging inside the retort chamber. In particular, the internal temperature of the product situated in the cold spot of the chamber has been monitored during 5 min of the process (after reaching 85°C inside the product) in order to monitor the time/temperature trend. Experimental tests have been finally performed to validate the simulation model of heat exchange. The sterilization process takes place in a retort chamber by means of "overheated water sprayed" at 403 K and a pressure of 5 atm. Results show a good agreement between the simulated results and the real retort process and confirm the potential value of the simulation model to evaluate the process performance.
2015
Three-dimensional cfd simulation of a "steam water spray" retort process for food vegetable products / Mosna, David; Vignali, Giuseppe. - In: INTERNATIONAL JOURNAL OF FOOD ENGINEERING. - ISSN 1556-3758. - 11:6(2015), pp. 715-729. [10.1515/ijfe-2015-0062]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2813767
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 9
social impact