Objectives: The introduction of diode lasers in dentistry had several advantages, principally consisting on the reduced size, reduced cost and possibility to beam delivering by optical fibbers. Up today only the wavelengths around 810 and 980 nm were the most utilized in oral surgery but recently more different lasers had been proposed. The aim of this study was to compare the efficacy of four diode laser wavelengths (810, 980, 1470 and 1950 nm) for the ablation of soft tissues. Material and methods: Specimens were surgically collected from the dorsal surface of four bovine tongues and irradiated by four different diode wavelengths. Thermal increase was measured by two thermocouples, the first at a depth of 0.5 mm, and the second at a depth of 2 mm. Initial and final surface temperatures were recorded by IR thermometer. Epithelial changes, connective tissue modifications, presence of vascular modification and incision morphology were histologically evaluated by two blind pathologists. Results: The time necessary to perform the excision varied between 271 seconds (808 nm, 2W) and 112 seconds (1950 nm, 4W). Temperature increase superficial level varied from 16.3° (980 nm, 4W) and 9.2° (1950 nm, 2 W). The most significant deep temperature increase was recorded by 980 nm, 4 W (17.3°) and the lowest by 1950 nm, 2 W (9.7°). The width of epithelial tissue injuries varied between 74 µm from 1950 nm diode laser at 2 W to 540 µm for 1470 nm diode laser at 4 W. Conclusion: The quality of incision was better and the width of overall tissue injuries was minor in the specimens obtained with higher wavelength (1950 nm) at lower power (2W).
Four different diode lasers comparison on soft tissues surgery: A preliminary ex vivo study / Fornaini, Carlo; Merigo, Elisabetta; Sozzi, Michele; Rocca, Jean Paul; Poli, Federica; Selleri, Stefano; Cucinotta, Annamaria. - In: LASER THERAPY. - ISSN 0898-5901. - 25:2(2016), pp. 105-114. [10.5978/islsm.16-OR-08]
Four different diode lasers comparison on soft tissues surgery: A preliminary ex vivo study
FORNAINI, Carlo;MERIGO, Elisabetta;SOZZI, MICHELE;POLI, Federica;SELLERI, Stefano;CUCINOTTA, Annamaria
2016-01-01
Abstract
Objectives: The introduction of diode lasers in dentistry had several advantages, principally consisting on the reduced size, reduced cost and possibility to beam delivering by optical fibbers. Up today only the wavelengths around 810 and 980 nm were the most utilized in oral surgery but recently more different lasers had been proposed. The aim of this study was to compare the efficacy of four diode laser wavelengths (810, 980, 1470 and 1950 nm) for the ablation of soft tissues. Material and methods: Specimens were surgically collected from the dorsal surface of four bovine tongues and irradiated by four different diode wavelengths. Thermal increase was measured by two thermocouples, the first at a depth of 0.5 mm, and the second at a depth of 2 mm. Initial and final surface temperatures were recorded by IR thermometer. Epithelial changes, connective tissue modifications, presence of vascular modification and incision morphology were histologically evaluated by two blind pathologists. Results: The time necessary to perform the excision varied between 271 seconds (808 nm, 2W) and 112 seconds (1950 nm, 4W). Temperature increase superficial level varied from 16.3° (980 nm, 4W) and 9.2° (1950 nm, 2 W). The most significant deep temperature increase was recorded by 980 nm, 4 W (17.3°) and the lowest by 1950 nm, 2 W (9.7°). The width of epithelial tissue injuries varied between 74 µm from 1950 nm diode laser at 2 W to 540 µm for 1470 nm diode laser at 4 W. Conclusion: The quality of incision was better and the width of overall tissue injuries was minor in the specimens obtained with higher wavelength (1950 nm) at lower power (2W).I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.