European and United States Pharmacopoeia compendial procedures for assessing the in vitro emitted dose and aerodynamic size distribution of a dry powder inhaler require that 4.0 L of air at a pressure drop of 4 kPa be drawn through the inhaler. However, the product performance should be investigated using conditions more representative of what is achievable by the patient population. This work compares the delivered dose and the drug deposition profile at different flow rates (30, 40, 60, and 90 L/min) of Foster NEXThaler(®) (beclomethasone dipropionate/formoterol fumarate), Seretide(®) Diskus(®) (fluticasone propionate/salmeterol xinafoate), and Symbicort(®) Turbohaler(®) (budesonide/formoterol fumarate).

Effect of Flow Rate on In Vitro Aerodynamic Performance of NEXThaler® in Comparison with Diskus® and Turbohaler® Dry Powder Inhalers / Buttini, Francesca; Brambilla, Gaetano; Copelli, Diego; Sisti, Viviana; Balducci, Anna Giulia; Bettini, Ruggero; Pasquali, Irene. - In: JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY. - ISSN 1941-2711. - 29:2(2016), pp. 167-178-178. [10.1089/jamp.2015.1220]

Effect of Flow Rate on In Vitro Aerodynamic Performance of NEXThaler® in Comparison with Diskus® and Turbohaler® Dry Powder Inhalers

BUTTINI, Francesca;BALDUCCI, Anna Giulia;BETTINI, Ruggero;PASQUALI, Irene
2016-01-01

Abstract

European and United States Pharmacopoeia compendial procedures for assessing the in vitro emitted dose and aerodynamic size distribution of a dry powder inhaler require that 4.0 L of air at a pressure drop of 4 kPa be drawn through the inhaler. However, the product performance should be investigated using conditions more representative of what is achievable by the patient population. This work compares the delivered dose and the drug deposition profile at different flow rates (30, 40, 60, and 90 L/min) of Foster NEXThaler(®) (beclomethasone dipropionate/formoterol fumarate), Seretide(®) Diskus(®) (fluticasone propionate/salmeterol xinafoate), and Symbicort(®) Turbohaler(®) (budesonide/formoterol fumarate).
2016
Effect of Flow Rate on In Vitro Aerodynamic Performance of NEXThaler® in Comparison with Diskus® and Turbohaler® Dry Powder Inhalers / Buttini, Francesca; Brambilla, Gaetano; Copelli, Diego; Sisti, Viviana; Balducci, Anna Giulia; Bettini, Ruggero; Pasquali, Irene. - In: JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY. - ISSN 1941-2711. - 29:2(2016), pp. 167-178-178. [10.1089/jamp.2015.1220]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2806313
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 84
  • ???jsp.display-item.citation.isi??? 76
social impact