Multi-source systems for the fulfillment of electric, thermal and cooling demand of a building can be based on different technologies (e.g. solar photovoltaic, solar heating, cogeneration, heat pump, absorption chiller) which use renewable, partially renewable and fossil energy sources. The main issues of these kinds of multi-source systems are (i) the allocation strategy which allows the division of the energy demands among the various technologies and (ii) the proper sizing of each technology. Furthermore, these two issues proves to be deeply interrelated because, while a wiser energy demand allocation strategy can lead to significant reductions in primary energy consumption, the definition itself of an optimal allocation strategy strongly depends on the actual sizing of the employed technologies. Thus the problem of optimizing the sizing of each technology cannot be separated from the definition of an optimal control strategy. For this purpose a model of a multi-source energy system, previously developed and implemented in the Matlab® environment, has been considered. The model takes account of the load profiles for electricity, heating and cooling for a whole year and the performance of the energy systems are modelled through a systemic approach. A dynamic programming algorithm is therefore employed in order to obtain an optimal control strategy for the energy demand allocation during the winter period. While the resulting control strategy is non-causal and therefore not suitable for the implementation on a real-time application, it allows the definition of a benchmark on the maximum primary energy savings achievable with a specific sizing solution. This result is therefore very helpful both in comparing different solutions and in subsequently define a proper causal control strategy. Finally, the model is applied to the case of a thirteen-floors tower composed of a two-floor shopping mall at ground level and eleven floors used as offices.

Optimization of Load Allocation Strategy of a Multi-source Energy System by Means of Dynamic Programming / Gambarotta, Agostino; Morini, Mirko; Pompini, Nicola; Spina, Pier Ruggero. - In: ENERGY PROCEDIA. - ISSN 1876-6102. - 81:(2015), pp. 30-39. (Intervento presentato al convegno ATI 2014 tenutosi a Milano) [10.1016/j.egypro.2015.12.056].

Optimization of Load Allocation Strategy of a Multi-source Energy System by Means of Dynamic Programming

GAMBAROTTA, Agostino;MORINI, Mirko;POMPINI, Nicola;
2015-01-01

Abstract

Multi-source systems for the fulfillment of electric, thermal and cooling demand of a building can be based on different technologies (e.g. solar photovoltaic, solar heating, cogeneration, heat pump, absorption chiller) which use renewable, partially renewable and fossil energy sources. The main issues of these kinds of multi-source systems are (i) the allocation strategy which allows the division of the energy demands among the various technologies and (ii) the proper sizing of each technology. Furthermore, these two issues proves to be deeply interrelated because, while a wiser energy demand allocation strategy can lead to significant reductions in primary energy consumption, the definition itself of an optimal allocation strategy strongly depends on the actual sizing of the employed technologies. Thus the problem of optimizing the sizing of each technology cannot be separated from the definition of an optimal control strategy. For this purpose a model of a multi-source energy system, previously developed and implemented in the Matlab® environment, has been considered. The model takes account of the load profiles for electricity, heating and cooling for a whole year and the performance of the energy systems are modelled through a systemic approach. A dynamic programming algorithm is therefore employed in order to obtain an optimal control strategy for the energy demand allocation during the winter period. While the resulting control strategy is non-causal and therefore not suitable for the implementation on a real-time application, it allows the definition of a benchmark on the maximum primary energy savings achievable with a specific sizing solution. This result is therefore very helpful both in comparing different solutions and in subsequently define a proper causal control strategy. Finally, the model is applied to the case of a thirteen-floors tower composed of a two-floor shopping mall at ground level and eleven floors used as offices.
2015
Optimization of Load Allocation Strategy of a Multi-source Energy System by Means of Dynamic Programming / Gambarotta, Agostino; Morini, Mirko; Pompini, Nicola; Spina, Pier Ruggero. - In: ENERGY PROCEDIA. - ISSN 1876-6102. - 81:(2015), pp. 30-39. (Intervento presentato al convegno ATI 2014 tenutosi a Milano) [10.1016/j.egypro.2015.12.056].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2799406
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 6
social impact