Objective The aim of this study was to evaluate the intraobserver and interobserver reproducibility of measurements, obtained from stored ultrasound volumes, related to fetal head progression in the birth canal. Methods From January to September 2009, serial ultrasound volumes were obtained from women in labor, stored and separately evaluated by two different operators using the SonoVCAD labor software. Volumes were aligned using the pubic bone and the urethra as references. In the sagittal plane of the pelvis, the following data were calculated: head progression distance (the distance between the infrapubic line and the lowest part of the fetal skull), head direction (the angle between the infrapubic line and the major longitudinal axis of the fetal head) and head progression angle (the angle between the longitudinal axis of the pubic bone and a line joining the lowest edge of the pubis to the lowest convexity of the fetal skull). In the transverse plane, the angle formed by the midline with the anteroposterior axis of the maternal pelvis (midline angle) was also measured. For each measurement, intraobserver and interobserver reproducibility was determined. Results We analyzed 30 ultrasound volumes. For all parameters, interobserver variation was significantly higher than intraobserver variation. Reproducibility was good for all parameters, except for the midline angle. Among the different ultrasound measurements, the progression angle presented the highest reproducibility. Conclusions Measurements obtained from stored ultrasound volumes to assess fetal head progression in the second stage of labor have good reproducibility, with progression distance and progression angle being the most reproducible parameters.

Three-dimensional ultrasound in monitoring progression of labor: a reproducibility study / Ghi, Tullio; Contro, E; Farina, A; Nobile, M; Pilu, G.. - In: ULTRASOUND IN OBSTETRICS & GYNECOLOGY. - ISSN 0960-7692. - 36:4(2010), pp. 500-6-506. [10.1002/uog.7752]

Three-dimensional ultrasound in monitoring progression of labor: a reproducibility study

GHI, Tullio;
2010-01-01

Abstract

Objective The aim of this study was to evaluate the intraobserver and interobserver reproducibility of measurements, obtained from stored ultrasound volumes, related to fetal head progression in the birth canal. Methods From January to September 2009, serial ultrasound volumes were obtained from women in labor, stored and separately evaluated by two different operators using the SonoVCAD labor software. Volumes were aligned using the pubic bone and the urethra as references. In the sagittal plane of the pelvis, the following data were calculated: head progression distance (the distance between the infrapubic line and the lowest part of the fetal skull), head direction (the angle between the infrapubic line and the major longitudinal axis of the fetal head) and head progression angle (the angle between the longitudinal axis of the pubic bone and a line joining the lowest edge of the pubis to the lowest convexity of the fetal skull). In the transverse plane, the angle formed by the midline with the anteroposterior axis of the maternal pelvis (midline angle) was also measured. For each measurement, intraobserver and interobserver reproducibility was determined. Results We analyzed 30 ultrasound volumes. For all parameters, interobserver variation was significantly higher than intraobserver variation. Reproducibility was good for all parameters, except for the midline angle. Among the different ultrasound measurements, the progression angle presented the highest reproducibility. Conclusions Measurements obtained from stored ultrasound volumes to assess fetal head progression in the second stage of labor have good reproducibility, with progression distance and progression angle being the most reproducible parameters.
2010
Three-dimensional ultrasound in monitoring progression of labor: a reproducibility study / Ghi, Tullio; Contro, E; Farina, A; Nobile, M; Pilu, G.. - In: ULTRASOUND IN OBSTETRICS & GYNECOLOGY. - ISSN 0960-7692. - 36:4(2010), pp. 500-6-506. [10.1002/uog.7752]
File in questo prodotto:
File Dimensione Formato  
published paper.pdf

solo utenti autorizzati

Descrizione: articolo principale
Tipologia: Altro materiale allegato
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 246.95 kB
Formato Adobe PDF
246.95 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2784478
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 59
  • ???jsp.display-item.citation.isi??? 45
social impact