In recent years, cogeneration systems have gained increasing attention especially when dealing with distributed generation for residential buildings. One of the main problems with using cogenerative systems in residential building applications is that the demand for heat and electricity is not synchronized. For this reason, when the Combined Heat and Power system operates during electricity peak hours (i.e. the rate of the electricity is higher), it could be profitable to store the heat in order to satisfy delayed demands. This paper presents a model for the calculation of the profitability of Micro Combined Heat and Power systems for residential building applications. The model takes into account hourly demands calculated by means of monthly and daily load profiles for heat and electricity. The system under consideration is composed of a CHP system, an auxiliary boiler and a heatstorage tank. The model is applied to a single-family dwelling in order to evaluate the effect of the size of the thermal energy storage unit on the energy and economic performance of four different prime movers (an internal combustion engine, a Stirling engine, a micro Rankine cycle and a thermophotovoltaic system).

Influence of the Thermal Energy Storage on the Profitability of Micro-CHP Systems for Residential Building Applications / E., Barbieri; F., Melino; Morini, Mirko. - (2011), pp. 2603-2616.

Influence of the Thermal Energy Storage on the Profitability of Micro-CHP Systems for Residential Building Applications

MORINI, Mirko
2011-01-01

Abstract

In recent years, cogeneration systems have gained increasing attention especially when dealing with distributed generation for residential buildings. One of the main problems with using cogenerative systems in residential building applications is that the demand for heat and electricity is not synchronized. For this reason, when the Combined Heat and Power system operates during electricity peak hours (i.e. the rate of the electricity is higher), it could be profitable to store the heat in order to satisfy delayed demands. This paper presents a model for the calculation of the profitability of Micro Combined Heat and Power systems for residential building applications. The model takes into account hourly demands calculated by means of monthly and daily load profiles for heat and electricity. The system under consideration is composed of a CHP system, an auxiliary boiler and a heatstorage tank. The model is applied to a single-family dwelling in order to evaluate the effect of the size of the thermal energy storage unit on the energy and economic performance of four different prime movers (an internal combustion engine, a Stirling engine, a micro Rankine cycle and a thermophotovoltaic system).
2011
Influence of the Thermal Energy Storage on the Profitability of Micro-CHP Systems for Residential Building Applications / E., Barbieri; F., Melino; Morini, Mirko. - (2011), pp. 2603-2616.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2757763
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 154
social impact