We aimed to evaluate the validity of lung lobe weight assessment via computed tomography (CT) by comparing CT-derived and ex vivo measurements.Unenhanced CT scanning was performed in 30 consecutive patients before lobectomy for lung cancer. The CT images were analyzed using research software after allowing for lobar weight quantitation. The lobar weight estimated by CT was then compared with that measured after surgery using a precision scale (ex vivo measurement). Comparisons as well as assessment of intra- and interoperator variability were conducted using the Bland-Altman method and the coefficient of repeatability (CR). Correlations were examined using Pearson's correlation analysis.Comparison analyses were feasible for 28 cases. The ex vivo lobe weight was 186.2±57.3 g, whereas the weights measured by the two operators by CT were 190.0±55 and 182.4±58.2 g, respectively. As compared with ex vivo weights, the CR was 36.4 for operator 1 and 50.4 for operator 2; the mean differences were 3.8 and -3.8 for operators 1 and 2, respectively. The intraoperator and interoperator CR were 20.9 and 36.6, respectively. The mean differences for the intra- and interoperator analysis were -1.5 and -7.5, respectively. The correlation was very high between CT-based and ex vivo measurements (r=0.95 and r=0.90 for operators 1 and 2, respectively; P < 0.001).Estimation of lung lobe weight by semi-automated CT analysis is sufficiently reproducible and in agreement with ex vivo measurements.
CT-based weight assessment of lung lobes: comparison with ex vivo measurements / Sverzellati, Nicola; Kuhnigk, Jan Martin; Furia, Simone; Diciotti, Stefano; Scanagatta, Paolo; Marchianò, Alfonso; Molinari, Francesco; Stoecker, Christina; Pastorino, Ugo. - In: DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY. - ISSN 1305-3825. - 19:(2013), pp. 355-359. [10.5152/dir.2013.149]
CT-based weight assessment of lung lobes: comparison with ex vivo measurements.
SVERZELLATI, Nicola;
2013-01-01
Abstract
We aimed to evaluate the validity of lung lobe weight assessment via computed tomography (CT) by comparing CT-derived and ex vivo measurements.Unenhanced CT scanning was performed in 30 consecutive patients before lobectomy for lung cancer. The CT images were analyzed using research software after allowing for lobar weight quantitation. The lobar weight estimated by CT was then compared with that measured after surgery using a precision scale (ex vivo measurement). Comparisons as well as assessment of intra- and interoperator variability were conducted using the Bland-Altman method and the coefficient of repeatability (CR). Correlations were examined using Pearson's correlation analysis.Comparison analyses were feasible for 28 cases. The ex vivo lobe weight was 186.2±57.3 g, whereas the weights measured by the two operators by CT were 190.0±55 and 182.4±58.2 g, respectively. As compared with ex vivo weights, the CR was 36.4 for operator 1 and 50.4 for operator 2; the mean differences were 3.8 and -3.8 for operators 1 and 2, respectively. The intraoperator and interoperator CR were 20.9 and 36.6, respectively. The mean differences for the intra- and interoperator analysis were -1.5 and -7.5, respectively. The correlation was very high between CT-based and ex vivo measurements (r=0.95 and r=0.90 for operators 1 and 2, respectively; P < 0.001).Estimation of lung lobe weight by semi-automated CT analysis is sufficiently reproducible and in agreement with ex vivo measurements.File | Dimensione | Formato | |
---|---|---|---|
Sverzellati DIR 2013.pdf
non disponibili
Tipologia:
Documento in Post-print
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
175.73 kB
Formato
Adobe PDF
|
175.73 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.