The reliability of a power converter can be improved using a well-dimensioned cold plate. At this aim it is necessary to realize a state of the art cold plate by means of thermal-fluid dynamic numerical analysis and ad-hoc designed experimental test bench. Features and metrological characterization of test bench for cold plate design and verification will be discussed in this paper.
Metrological characterization of a cold plate test bench / M., Lazzaroni; M., Citterio; S., Latorre; A., Lanza; Cova, Paolo; Delmonte, Nicola; Giuliani, Francesco. - ELETTRONICO. - (2014), pp. 386-391. (Intervento presentato al convegno 2014 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) tenutosi a Montevideo, Uruguay nel 12-15 maggio 2014) [10.1109/I2MTC.2014.6860773].
Metrological characterization of a cold plate test bench
COVA, Paolo;DELMONTE, Nicola;GIULIANI, Francesco
2014-01-01
Abstract
The reliability of a power converter can be improved using a well-dimensioned cold plate. At this aim it is necessary to realize a state of the art cold plate by means of thermal-fluid dynamic numerical analysis and ad-hoc designed experimental test bench. Features and metrological characterization of test bench for cold plate design and verification will be discussed in this paper.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.