To verify the reliability of quantitative computed tomography (CT) to estimate the postoperative lung function in patients with mild to severe chronic obstructive pulmonary disease (COPD) who underwent a lobectomy.Nine COPD patients with lung cancer having a lung lobectomy with preoperative CT were enrolled. By applying a density mask technique and a specific equation, predicted postoperative forced expiratory volume in 1 second (FEV1) and vital capacity (VC) were calculated. Predicted values were correlated with postoperative measured values.Estimated FEV1 and VC were always significantly lower than the corresponding postoperative values; however, CT-estimated postresection FEV1 values were better than the postresection VC values (biases between estimated and measured values were -0.14 and -0.536 L, respectively, according to the Bland-Altman method). Quantitative CT predicted postoperative FEV1 (r = 0.97, P < 0.001) and VC (r = 0.93, P < 0.001) well in all patients, however.Quantitative CT may be an alternative tool to perfusion scan to predict postresection lung function, even in patients with borderline pulmonary function undergoing a lobectomy.

Reliability of quantitative computed tomography to predict postoperative lung function in patients with chronic obstructive pulmonary disease having a lobectomy / Sverzellati, Nicola; Chetta, Alfredo Antonio; Calabrò, Elisa; Carbognani, Paolo; Internullo, Eveline; Olivieri, Dario; Zompatori, Maurizio. - In: JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY. - ISSN 0363-8715. - 29:6(2005), pp. 819-824. [10.1097/01.rct.0000179595.09092.ee]

Reliability of quantitative computed tomography to predict postoperative lung function in patients with chronic obstructive pulmonary disease having a lobectomy.

SVERZELLATI, Nicola;CHETTA, Alfredo Antonio;CARBOGNANI, Paolo;OLIVIERI, Dario;
2005-01-01

Abstract

To verify the reliability of quantitative computed tomography (CT) to estimate the postoperative lung function in patients with mild to severe chronic obstructive pulmonary disease (COPD) who underwent a lobectomy.Nine COPD patients with lung cancer having a lung lobectomy with preoperative CT were enrolled. By applying a density mask technique and a specific equation, predicted postoperative forced expiratory volume in 1 second (FEV1) and vital capacity (VC) were calculated. Predicted values were correlated with postoperative measured values.Estimated FEV1 and VC were always significantly lower than the corresponding postoperative values; however, CT-estimated postresection FEV1 values were better than the postresection VC values (biases between estimated and measured values were -0.14 and -0.536 L, respectively, according to the Bland-Altman method). Quantitative CT predicted postoperative FEV1 (r = 0.97, P < 0.001) and VC (r = 0.93, P < 0.001) well in all patients, however.Quantitative CT may be an alternative tool to perfusion scan to predict postresection lung function, even in patients with borderline pulmonary function undergoing a lobectomy.
2005
Reliability of quantitative computed tomography to predict postoperative lung function in patients with chronic obstructive pulmonary disease having a lobectomy / Sverzellati, Nicola; Chetta, Alfredo Antonio; Calabrò, Elisa; Carbognani, Paolo; Internullo, Eveline; Olivieri, Dario; Zompatori, Maurizio. - In: JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY. - ISSN 0363-8715. - 29:6(2005), pp. 819-824. [10.1097/01.rct.0000179595.09092.ee]
File in questo prodotto:
File Dimensione Formato  
Reliability of Quantitative Computed Tomography..... JCAT 05.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 446.53 kB
Formato Adobe PDF
446.53 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2338450
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 16
social impact