To assess in vivo volumetric repeatability of an automated software algorithm in pulmonary nodules detected during a lung cancer screening trial.This study was approved by an institutional review board. Written informed consent was obtained from all participants. Data were collected from the Multicentric Italian Lung Detection project, a randomized controlled lung cancer screening trial. The first 1236 consecutive baseline computed tomographic (CT) studies performed at the Istituto Nazionale Tumori of Milan were evaluated. Among the enrolled participants, those who underwent repeat low-dose CT after 3 months and had at least one indeterminate nodule with a volume of more than 60 mm(3) (diameter of 4.8 mm or greater) were considered. Nonsolid, part-solid, and pleural-based nodules were excluded from this study. A descriptive analysis was performed by calculating means and standard deviations of nodule volumes at three assessment times (at baseline and 3 and 12 months later). The volume measurement repeatability was determined by using the approach described by Bland and Altman.One hundred one subjects (70 men, 31 women; mean age, 58 years) with 233 eligible nodules (mean volume, 98.3 mm(3); range, 5-869 mm(3)) were identified. The 95\% confidence interval for difference in measured volumes was in the range of +/-27\%. About 70\% of measurements had a relative difference in nodule volume of less than 10\%. No malignant lesions were registered during the follow-up of these subjects.Semiautomatic volumetry is sufficiently accurate and repeatable and may be useful in assisting with lung nodule management in a lung cancer screening program.

Pulmonary nodules: volume repeatability at multidetector CT lung cancer screening / Marchianò, Alfonso; Calabrò, Elisa; Civelli, Enrico; Di Tolla, Giuseppe; Frigerio, Laura F; Morosi, Carlo; Tafaro, Francesco; Ferri, Elena; Sverzellati, Nicola; Camerini, Tiziana; Mariani, Luigi; Lo Vullo, Salvatore; Pastorino, Ugo. - In: RADIOLOGY. - ISSN 0033-8419. - 251:(2009), pp. 919-925. [10.1148/radiol.2513081313]

Pulmonary nodules: volume repeatability at multidetector CT lung cancer screening.

SVERZELLATI, Nicola;
2009-01-01

Abstract

To assess in vivo volumetric repeatability of an automated software algorithm in pulmonary nodules detected during a lung cancer screening trial.This study was approved by an institutional review board. Written informed consent was obtained from all participants. Data were collected from the Multicentric Italian Lung Detection project, a randomized controlled lung cancer screening trial. The first 1236 consecutive baseline computed tomographic (CT) studies performed at the Istituto Nazionale Tumori of Milan were evaluated. Among the enrolled participants, those who underwent repeat low-dose CT after 3 months and had at least one indeterminate nodule with a volume of more than 60 mm(3) (diameter of 4.8 mm or greater) were considered. Nonsolid, part-solid, and pleural-based nodules were excluded from this study. A descriptive analysis was performed by calculating means and standard deviations of nodule volumes at three assessment times (at baseline and 3 and 12 months later). The volume measurement repeatability was determined by using the approach described by Bland and Altman.One hundred one subjects (70 men, 31 women; mean age, 58 years) with 233 eligible nodules (mean volume, 98.3 mm(3); range, 5-869 mm(3)) were identified. The 95\% confidence interval for difference in measured volumes was in the range of +/-27\%. About 70\% of measurements had a relative difference in nodule volume of less than 10\%. No malignant lesions were registered during the follow-up of these subjects.Semiautomatic volumetry is sufficiently accurate and repeatable and may be useful in assisting with lung nodule management in a lung cancer screening program.
2009
Pulmonary nodules: volume repeatability at multidetector CT lung cancer screening / Marchianò, Alfonso; Calabrò, Elisa; Civelli, Enrico; Di Tolla, Giuseppe; Frigerio, Laura F; Morosi, Carlo; Tafaro, Francesco; Ferri, Elena; Sverzellati, Nicola; Camerini, Tiziana; Mariani, Luigi; Lo Vullo, Salvatore; Pastorino, Ugo. - In: RADIOLOGY. - ISSN 0033-8419. - 251:(2009), pp. 919-925. [10.1148/radiol.2513081313]
File in questo prodotto:
File Dimensione Formato  
Pulmonary Nodules-Volume Repeatibility at MDCT Lung Cancer Screening Radiology 09.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 345.83 kB
Formato Adobe PDF
345.83 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2338423
Citazioni
  • ???jsp.display-item.citation.pmc??? 21
  • Scopus 65
  • ???jsp.display-item.citation.isi??? 65
social impact