This paper describes an approach to the design of optimum QRS detectors. We report on detectors including a linear or nonlinear polynomial filter, which enhances and rectifies the QRS complex, and a simple, adaptive maxima detector. The parameters of the filter and the detector, and the samples to be processed are selected by a genetic algorithm which minimizes the deletion errors made on a set of reference ECG signals. Three different architectures and the experimental results achieved on the MIT-BIH Arrhythmia Database are described. This paper describes an approach to the design of optimum QRS detectors. We report on detectors including a linear or nonlinear polynomial filter, which enhances and rectifies the QRS complex, and a simple, adaptive maxima detector. The parameters of the filter and the detector, and the samples to be processed are selected by a genetic algorithm which minimizes the detection errors made on a set of reference ECG signals. Three different architectures and the experimental results achieved on the MIT-BIH Arrhythmia Database are described.

Genetic design of optimum linear and non-linear QRS detectors / Poli, R; Cagnoni, Stefano; Valli, G.. - In: IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING. - ISSN 0018-9294. - 42:(1995), pp. 1137-1141. [10.1109/10.469381]

Genetic design of optimum linear and non-linear QRS detectors

CAGNONI, Stefano;
1995-01-01

Abstract

This paper describes an approach to the design of optimum QRS detectors. We report on detectors including a linear or nonlinear polynomial filter, which enhances and rectifies the QRS complex, and a simple, adaptive maxima detector. The parameters of the filter and the detector, and the samples to be processed are selected by a genetic algorithm which minimizes the deletion errors made on a set of reference ECG signals. Three different architectures and the experimental results achieved on the MIT-BIH Arrhythmia Database are described. This paper describes an approach to the design of optimum QRS detectors. We report on detectors including a linear or nonlinear polynomial filter, which enhances and rectifies the QRS complex, and a simple, adaptive maxima detector. The parameters of the filter and the detector, and the samples to be processed are selected by a genetic algorithm which minimizes the detection errors made on a set of reference ECG signals. Three different architectures and the experimental results achieved on the MIT-BIH Arrhythmia Database are described.
1995
Genetic design of optimum linear and non-linear QRS detectors / Poli, R; Cagnoni, Stefano; Valli, G.. - In: IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING. - ISSN 0018-9294. - 42:(1995), pp. 1137-1141. [10.1109/10.469381]
File in questo prodotto:
File Dimensione Formato  
00469381.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 502.87 kB
Formato Adobe PDF
502.87 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2315906
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 188
  • ???jsp.display-item.citation.isi??? 156
social impact