An experimental analysis and a data processing procedure, aimed to the characterization of an uncooled microbolometric infrared camera, have been carried out. The instrument performance test is addressed to the application of infrared thermography to the parameter estimation problem based on the solution of the inverse heat conduction problem. With this regard, a new figure of merit, which enables to estimate the local noise level in the thermal image, has been suggested. This parameter may be used to characterize the performance of IR and also of other thermographic devices, for applications common to a wide category of heat transfer measurements in which the spatial first or second derivatives of a thermal two-dimensional signal are needed. The instrument has been compared, in terms of local noise level, to an IR camera based on the cooled photon detector array technology.

Characterization of an Uncooled Infrared Thermographic System Suitable for the Solution of the 2-D Inverse Heat Conduction Problem / Rainieri, Sara; Bozzoli, Fabio; Pagliarini, Giorgio. - In: EXPERIMENTAL THERMAL AND FLUID SCIENCE. - ISSN 0894-1777. - 32, Issue 8:(2008), pp. 1492-1498. [10.1016/j.expthermflusci.2008.03.006]

Characterization of an Uncooled Infrared Thermographic System Suitable for the Solution of the 2-D Inverse Heat Conduction Problem

RAINIERI, Sara;BOZZOLI, Fabio;PAGLIARINI, Giorgio
2008-01-01

Abstract

An experimental analysis and a data processing procedure, aimed to the characterization of an uncooled microbolometric infrared camera, have been carried out. The instrument performance test is addressed to the application of infrared thermography to the parameter estimation problem based on the solution of the inverse heat conduction problem. With this regard, a new figure of merit, which enables to estimate the local noise level in the thermal image, has been suggested. This parameter may be used to characterize the performance of IR and also of other thermographic devices, for applications common to a wide category of heat transfer measurements in which the spatial first or second derivatives of a thermal two-dimensional signal are needed. The instrument has been compared, in terms of local noise level, to an IR camera based on the cooled photon detector array technology.
2008
Characterization of an Uncooled Infrared Thermographic System Suitable for the Solution of the 2-D Inverse Heat Conduction Problem / Rainieri, Sara; Bozzoli, Fabio; Pagliarini, Giorgio. - In: EXPERIMENTAL THERMAL AND FLUID SCIENCE. - ISSN 0894-1777. - 32, Issue 8:(2008), pp. 1492-1498. [10.1016/j.expthermflusci.2008.03.006]
File in questo prodotto:
File Dimensione Formato  
EXTFS_08.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 281.63 kB
Formato Adobe PDF
281.63 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2296209
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 24
social impact