In grid connected power converters both from renewable or traditional energy sources a line frequency transformer is usually employed in order to suppress the DC component. Recently, solutions based on a high frequency transformer or without transformer, usually referred as transformerless, are being investigated in order to reduce size, weight and costs. As a consequence, unless a suitable remedy is adopted, a DC component, that might overcome limits forced by international standards, may appear. This paper proposes a simple and cheap solution to reduce the DC current component injected into the grid in case of a full-bridge, single phase, transformerless converter. The proposed strategy is intrinsically insensitive to offset measurement errors and can be utilized as a robust and dynamic offset compensator for the Hall effect sensor mostly used as current transducer. Experimental results, performed for different current values and for different current control architectures, show the effectiveness of the proposed solution.

A Novel Current Sensing DC Offset Compensation Strategy in Transformerless Grid Connected Power Converters / Lorenzani, E; Franceschini, Giovanni; Tassoni, Carla; Bellini, A; Buticchi, Giampaolo. - (2009), pp. 1-6. (Intervento presentato al convegno IEEE ECCE 2009 tenutosi a San Jose California nel 20-24 September 2009) [10.1109/ECCE.2009.5316339].

A Novel Current Sensing DC Offset Compensation Strategy in Transformerless Grid Connected Power Converters

FRANCESCHINI, Giovanni;TASSONI, Carla;BUTICCHI, Giampaolo
2009-01-01

Abstract

In grid connected power converters both from renewable or traditional energy sources a line frequency transformer is usually employed in order to suppress the DC component. Recently, solutions based on a high frequency transformer or without transformer, usually referred as transformerless, are being investigated in order to reduce size, weight and costs. As a consequence, unless a suitable remedy is adopted, a DC component, that might overcome limits forced by international standards, may appear. This paper proposes a simple and cheap solution to reduce the DC current component injected into the grid in case of a full-bridge, single phase, transformerless converter. The proposed strategy is intrinsically insensitive to offset measurement errors and can be utilized as a robust and dynamic offset compensator for the Hall effect sensor mostly used as current transducer. Experimental results, performed for different current values and for different current control architectures, show the effectiveness of the proposed solution.
2009
A Novel Current Sensing DC Offset Compensation Strategy in Transformerless Grid Connected Power Converters / Lorenzani, E; Franceschini, Giovanni; Tassoni, Carla; Bellini, A; Buticchi, Giampaolo. - (2009), pp. 1-6. (Intervento presentato al convegno IEEE ECCE 2009 tenutosi a San Jose California nel 20-24 September 2009) [10.1109/ECCE.2009.5316339].
File in questo prodotto:
File Dimensione Formato  
2009_ECCE_DC_Offset.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 478.7 kB
Formato Adobe PDF
478.7 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2294461
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? ND
social impact