In domestic grid connected PV applications a single phase converter is usually used. In such a low power plants it is possible to adopt converter topologies without galvanic isolation between the photovoltaic panels and the grid. The absence of a high or low frequency transformer permits to reduce power losses, cost and size of the converter. On the other side in presence of a galvanic connection a large ground leakage current could arise due to parasitic PV panel capacitance. Leakage currents cause electric safety problems, EMI increase and, consequently, a reduction of the converter power quality. This paper presents a converter topology able to minimize the ground leakage current also in case of unipolar PWM modulation without increasing inductive common mode filter size and preserving efficiency. Simulations and experimental results show the feasibility of the proposed solution.

A NEW PROPOSAL FOR GROUND LEAKAGE CURRENT REDUCTION IN TRANSFORMERLESS GRID-CONNECTED CONVERTERS FOR PHOTOVOLTAIC PLANTS / Barater, Davide; Buticchi, Giampaolo; Crinto, A. S.; Lorenzani, E; Franceschini, Giovanni. - (2009), pp. 1-6. (Intervento presentato al convegno IEEE IECON 2009 tenutosi a Porto nel 3-5 November 2009) [10.1109/IECON.2009.5414874].

A NEW PROPOSAL FOR GROUND LEAKAGE CURRENT REDUCTION IN TRANSFORMERLESS GRID-CONNECTED CONVERTERS FOR PHOTOVOLTAIC PLANTS

BARATER, Davide;BUTICCHI, Giampaolo;FRANCESCHINI, Giovanni
2009-01-01

Abstract

In domestic grid connected PV applications a single phase converter is usually used. In such a low power plants it is possible to adopt converter topologies without galvanic isolation between the photovoltaic panels and the grid. The absence of a high or low frequency transformer permits to reduce power losses, cost and size of the converter. On the other side in presence of a galvanic connection a large ground leakage current could arise due to parasitic PV panel capacitance. Leakage currents cause electric safety problems, EMI increase and, consequently, a reduction of the converter power quality. This paper presents a converter topology able to minimize the ground leakage current also in case of unipolar PWM modulation without increasing inductive common mode filter size and preserving efficiency. Simulations and experimental results show the feasibility of the proposed solution.
2009
A NEW PROPOSAL FOR GROUND LEAKAGE CURRENT REDUCTION IN TRANSFORMERLESS GRID-CONNECTED CONVERTERS FOR PHOTOVOLTAIC PLANTS / Barater, Davide; Buticchi, Giampaolo; Crinto, A. S.; Lorenzani, E; Franceschini, Giovanni. - (2009), pp. 1-6. (Intervento presentato al convegno IEEE IECON 2009 tenutosi a Porto nel 3-5 November 2009) [10.1109/IECON.2009.5414874].
File in questo prodotto:
File Dimensione Formato  
2009_IECON_New_Proposal_Transformerless.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 551.14 kB
Formato Adobe PDF
551.14 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2285254
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 31
  • ???jsp.display-item.citation.isi??? 0
social impact