The new Vidia system is a fully automated system based on chemiluminescence and antigen bound to magnetic microparticles, which allows a fast measurement of Toxoplasma gondii-specific immunoglobulin G (IgG) and IgM levels. The analytical performances of the Vidia Toxo IgG and IgM assays were compared with those of the automated Vidas, AxSYM, and Liaison Toxo IgG and IgM assays. The comparative evaluation was performed utilizing 204 frozen sera belonging to 166 subjects and 201 fresh sera collected from 198 subjects. For the Vidia Toxo IgG system, the sensitivities were 100% in both the retrospective and prospective studies, and specificities were 98.39% in the retrospective study and 100% in the prospective study, respectively. The sensitivities of the other three Toxo IgG assays were 100%, and the specificities ranged from 96.77% to 100%. For the Vidia Toxo IgM assay, the sensitivity and specificity were 100% in both the retrospective and prospective studies. The overall sensitivities and specificities of the other three Toxo IgM assays ranged from 80% to 100% and from 99.44% to 100%, respectively. In our study, the Vidia system revealed excellent sensitivity (100% for both IgG and IgM assays) and good specificity (99.25% for IgG and 100% for IgM assays).

Evaluation of Toxoplasma gondii immunoglobulin G (IgG) and IgM assays incorporating the new Vidia analyser system / Calderaro, Adriana; Piccolo, Giovanna; Peruzzi, Simona; Gorrini, Chiara; Chezzi, Carlo; Dettori, Giuseppe. - In: CLINICAL AND VACCINE IMMUNOLOGY. - ISSN 1556-6811. - 15 (7):(2008), pp. 1076-1079. [10.1128/CVI.00025-08]

Evaluation of Toxoplasma gondii immunoglobulin G (IgG) and IgM assays incorporating the new Vidia analyser system

CALDERARO, Adriana;PICCOLO, Giovanna;PERUZZI, Simona;GORRINI, Chiara;CHEZZI, Carlo;DETTORI, Giuseppe
2008-01-01

Abstract

The new Vidia system is a fully automated system based on chemiluminescence and antigen bound to magnetic microparticles, which allows a fast measurement of Toxoplasma gondii-specific immunoglobulin G (IgG) and IgM levels. The analytical performances of the Vidia Toxo IgG and IgM assays were compared with those of the automated Vidas, AxSYM, and Liaison Toxo IgG and IgM assays. The comparative evaluation was performed utilizing 204 frozen sera belonging to 166 subjects and 201 fresh sera collected from 198 subjects. For the Vidia Toxo IgG system, the sensitivities were 100% in both the retrospective and prospective studies, and specificities were 98.39% in the retrospective study and 100% in the prospective study, respectively. The sensitivities of the other three Toxo IgG assays were 100%, and the specificities ranged from 96.77% to 100%. For the Vidia Toxo IgM assay, the sensitivity and specificity were 100% in both the retrospective and prospective studies. The overall sensitivities and specificities of the other three Toxo IgM assays ranged from 80% to 100% and from 99.44% to 100%, respectively. In our study, the Vidia system revealed excellent sensitivity (100% for both IgG and IgM assays) and good specificity (99.25% for IgG and 100% for IgM assays).
2008
Evaluation of Toxoplasma gondii immunoglobulin G (IgG) and IgM assays incorporating the new Vidia analyser system / Calderaro, Adriana; Piccolo, Giovanna; Peruzzi, Simona; Gorrini, Chiara; Chezzi, Carlo; Dettori, Giuseppe. - In: CLINICAL AND VACCINE IMMUNOLOGY. - ISSN 1556-6811. - 15 (7):(2008), pp. 1076-1079. [10.1128/CVI.00025-08]
File in questo prodotto:
File Dimensione Formato  
Calderaro A et al., 2008b.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 52.67 kB
Formato Adobe PDF
52.67 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/1846962
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 18
social impact