Abstract. Aim of this work is to illustrate how analytical interference in immunoassay may produce serious errors in clinical laboratory results. The sophisticated quality assurance schemes used in many laboratories do not identify erroneous results arising from aberrant samples. Recently attention has been focused on the incidence and implication of false-positive results arising from the presence of certain substances in a patient’s serum that interfere with one or more steps in immunoassays. In this paper, we present the case of a 92 yearold woman whose plasma myoglobin concentrations falsely increased when measured using the Beckman Access assay. We demonstrated that heterophilic antibodies accounted for the falsely increased myoglobin values, and we suggest how to resolve such situations. (www.actabiomedica.it) Key words: Heterophilic antibodies, immunoassays, myoglobin values, blocking tube
Interference by heterophilic antibodies in immunoassays: wrong increase of myoglobin values / Bonetti, Antonio; Monica, C; Bonaguri, C; Gnocchi, C; Russo, A; Battistelli, L; Musiari, Luisa; Pastori, P; Novarini, A.. - In: ACTA BIO-MEDICA DE L'ATENEO PARMENSE. - ISSN 0392-4203. - 79:(2008), pp. 140-143.
Interference by heterophilic antibodies in immunoassays: wrong increase of myoglobin values.
BONETTI, Antonio;MUSIARI, Luisa;
2008-01-01
Abstract
Abstract. Aim of this work is to illustrate how analytical interference in immunoassay may produce serious errors in clinical laboratory results. The sophisticated quality assurance schemes used in many laboratories do not identify erroneous results arising from aberrant samples. Recently attention has been focused on the incidence and implication of false-positive results arising from the presence of certain substances in a patient’s serum that interfere with one or more steps in immunoassays. In this paper, we present the case of a 92 yearold woman whose plasma myoglobin concentrations falsely increased when measured using the Beckman Access assay. We demonstrated that heterophilic antibodies accounted for the falsely increased myoglobin values, and we suggest how to resolve such situations. (www.actabiomedica.it) Key words: Heterophilic antibodies, immunoassays, myoglobin values, blocking tubeFile | Dimensione | Formato | |
---|---|---|---|
Prof.Bonetti Acta Biomed 2008.pdf
non disponibili
Tipologia:
Documento in Post-print
Licenza:
Creative commons
Dimensione
48.77 kB
Formato
Adobe PDF
|
48.77 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.