An investigation of the color metrics and the complexity of the CIEDE2000 formula shows that CIELAB space is inadequate to represent small–medium color differences. The OSA-UCS (Uniform Color Space) Committee has shown that no space with uniform scale for large color differences exists. Therefore the practical way for color-difference specification is a color-difference formula in a non uniform space. First, the BFD (Bradford University) ellipses are considered in the OSA-UCS space, and their very high regularity suggests a new and very simple color-difference formula at constant luminance. Then the COM (combined) data set used for the development of the CIEDE2000 formula is considered in the OSA-UCS space, and the color-difference formula is extended to sample pairs with a different luminance factor. The value of the performance factor PF/3 for the proposed OSA-UCS-based formula shows that the formula performs like the more complex CIEDE2000 formula for small–medium color differences.
Performance of a color-difference formula based on OSA-UCS space using small-medium color differences / Huertas, R; Melgosa, M; Oleari, Claudio. - In: JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION. - ISSN 1084-7529. - 23:(2006), pp. 2077-2084. [10.1364/JOSAA.23.002077]
Performance of a color-difference formula based on OSA-UCS space using small-medium color differences
OLEARI, Claudio
2006-01-01
Abstract
An investigation of the color metrics and the complexity of the CIEDE2000 formula shows that CIELAB space is inadequate to represent small–medium color differences. The OSA-UCS (Uniform Color Space) Committee has shown that no space with uniform scale for large color differences exists. Therefore the practical way for color-difference specification is a color-difference formula in a non uniform space. First, the BFD (Bradford University) ellipses are considered in the OSA-UCS space, and their very high regularity suggests a new and very simple color-difference formula at constant luminance. Then the COM (combined) data set used for the development of the CIEDE2000 formula is considered in the OSA-UCS space, and the color-difference formula is extended to sample pairs with a different luminance factor. The value of the performance factor PF/3 for the proposed OSA-UCS-based formula shows that the formula performs like the more complex CIEDE2000 formula for small–medium color differences.File | Dimensione | Formato | |
---|---|---|---|
AbstractOleariJourOptSocAmerA23-2077.docx
non disponibili
Tipologia:
Abstract
Licenza:
Creative commons
Dimensione
12.09 kB
Formato
Microsoft Word XML
|
12.09 kB | Microsoft Word XML | Visualizza/Apri Richiedi una copia |
2006_JOSA_Huertas-Melgosa-Oleari.pdf
non disponibili
Tipologia:
Documento in Post-print
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
368.55 kB
Formato
Adobe PDF
|
368.55 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.