Among hospital facilities the dental unit is an environment that is at major risk of Legionella due to equipment such as the air/water syringe, the turbine, the micromotor and the scaler which generate potentially harmful aerosols that may to be a source of exposure to Legionella spp. Therefore, an examination of the extent of Legionella spp. contamination in the dental chairs waterlines and the incoming water supply of some public dental units is the subject of the present study. From February 2002 to March 2004, a total of 208 water samples were collected: 160 samples from the water supply of 4 dental chair and 48 samples from the cold incoming tap water of 2 units. Legionella spp. was detected in 46 samples (22.1% ): 19 of them (41.3% of Legionella spp.; 9.1% of the total) were Legionella pneumophila; Pseudomonas aeruginosa was detected in 86 samples (41.4%) and both microorganisms were detected in 2 samples (0.96%). Our results show a microbiological condition in dental settings, that is not at all satisfactory due to the presence of Legionella in concentrations that are considered to be a health hazard (> or = 10(3)) in certain cases. Given the extent of the health risk in these surroundings, the difficulty in its assessment, and also considering the wide diffusion of general dental care, our investigation has confirmed the need to regularly monitor the microbiological condition of water in dental units.

Legionella spp. in hospital dental facilities / Tanzi, Maria Luisa; Capobianco, E; Affanni, Paola; Pizzi, Silvia; Vitali, P; Veronesi, Licia. - In: THE JOURNAL OF HOSPITAL INFECTION. - ISSN 0195-6701. - 63(2):(2006), pp. 232-234. [10.1016/j.jhin.2006.01.026]

Legionella spp. in hospital dental facilities.

TANZI, Maria Luisa;CAPOBIANCO E;AFFANNI, Paola;PIZZI, Silvia;VERONESI, Licia
2006-01-01

Abstract

Among hospital facilities the dental unit is an environment that is at major risk of Legionella due to equipment such as the air/water syringe, the turbine, the micromotor and the scaler which generate potentially harmful aerosols that may to be a source of exposure to Legionella spp. Therefore, an examination of the extent of Legionella spp. contamination in the dental chairs waterlines and the incoming water supply of some public dental units is the subject of the present study. From February 2002 to March 2004, a total of 208 water samples were collected: 160 samples from the water supply of 4 dental chair and 48 samples from the cold incoming tap water of 2 units. Legionella spp. was detected in 46 samples (22.1% ): 19 of them (41.3% of Legionella spp.; 9.1% of the total) were Legionella pneumophila; Pseudomonas aeruginosa was detected in 86 samples (41.4%) and both microorganisms were detected in 2 samples (0.96%). Our results show a microbiological condition in dental settings, that is not at all satisfactory due to the presence of Legionella in concentrations that are considered to be a health hazard (> or = 10(3)) in certain cases. Given the extent of the health risk in these surroundings, the difficulty in its assessment, and also considering the wide diffusion of general dental care, our investigation has confirmed the need to regularly monitor the microbiological condition of water in dental units.
2006
Legionella spp. in hospital dental facilities / Tanzi, Maria Luisa; Capobianco, E; Affanni, Paola; Pizzi, Silvia; Vitali, P; Veronesi, Licia. - In: THE JOURNAL OF HOSPITAL INFECTION. - ISSN 0195-6701. - 63(2):(2006), pp. 232-234. [10.1016/j.jhin.2006.01.026]
File in questo prodotto:
File Dimensione Formato  
lEGIONELLA SPP. IN HOSPITAL DENTAL FACILITIES.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 63.39 kB
Formato Adobe PDF
63.39 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/1500340
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 6
social impact