Introduction: Fibroblastic sheath formation is a well-known complication of long-term central venous catheters. When calcified, fibroblastic (formerly known as "fibrin") sheaths may be easily mistaken for retained catheter fragments. We describe one such case and how imaging was used to recognize the sheath and avoid unnecessary interventions. Case Description: A patient with systemic sclerosis was referred for port removal because of suspected infection. A later computed tomography scan showed a persistent tubular structure coursing behind the right clavicle, which was also seen in an anteroposterior chest radiograph. Three-dimensional reconstruction and analysis of the structure's lumen in comparison to previous imaging studies allowed us to confirm that it was, in fact, a calcified fibroblastic sheath. The patient's course was uneventful thereafter. Conclusion: Three-dimensional computed tomography reconstruction, as well as the hollow appearance of a tubular structure after removal of a central catheter may help differentiate a fibroblastic sheath from a retained catheter fragment. Accurate surgical notes mentioning the length of the catheter at implant and explant are also of paramount importance.

If it looks like a catheter and winds like a catheter . . . fibroblastic sheath mimicking a central venous catheter fragment: A case report / Baciarello, Marco; Maspero, Giada; Maestroni, Umberto; Palumbo, Giuseppina; Bellini, Valentina; Bignami, Elena. - In: JOURNAL OF VASCULAR ACCESS. - ISSN 1129-7298. - 21:4(2020), pp. 529-532. [10.1177/1129729819873488]

If it looks like a catheter and winds like a catheter . . . fibroblastic sheath mimicking a central venous catheter fragment: A case report

Baciarello, Marco;Maspero, Giada;Maestroni, Umberto;Palumbo, Giuseppina;Bignami, Elena
2020-01-01

Abstract

Introduction: Fibroblastic sheath formation is a well-known complication of long-term central venous catheters. When calcified, fibroblastic (formerly known as "fibrin") sheaths may be easily mistaken for retained catheter fragments. We describe one such case and how imaging was used to recognize the sheath and avoid unnecessary interventions. Case Description: A patient with systemic sclerosis was referred for port removal because of suspected infection. A later computed tomography scan showed a persistent tubular structure coursing behind the right clavicle, which was also seen in an anteroposterior chest radiograph. Three-dimensional reconstruction and analysis of the structure's lumen in comparison to previous imaging studies allowed us to confirm that it was, in fact, a calcified fibroblastic sheath. The patient's course was uneventful thereafter. Conclusion: Three-dimensional computed tomography reconstruction, as well as the hollow appearance of a tubular structure after removal of a central catheter may help differentiate a fibroblastic sheath from a retained catheter fragment. Accurate surgical notes mentioning the length of the catheter at implant and explant are also of paramount importance.
2020
If it looks like a catheter and winds like a catheter . . . fibroblastic sheath mimicking a central venous catheter fragment: A case report / Baciarello, Marco; Maspero, Giada; Maestroni, Umberto; Palumbo, Giuseppina; Bellini, Valentina; Bignami, Elena. - In: JOURNAL OF VASCULAR ACCESS. - ISSN 1129-7298. - 21:4(2020), pp. 529-532. [10.1177/1129729819873488]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2933761
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact