In this paper, we present a simple way to place the implant into a harvested pocket and to subsequently fix it percutaneously. Eighteen patients (1 male, 13 females, 4 transgender), underwent facial implant placement; a total of 31 implants were placed (1 pair of angles of the mandible implants, 12 pairs of malar/sub-malar implants, and 5 chin implants). The intraoral approach was performed on 15 patients, and on the remaining three patients, the sub-ciliary lower lid approach was preferred. Patients were followed up for at least one year with a maximum follow-up of seven years (mean 1.8 years). In all the cases, except one, patients healed without complications. One case of implant displacement and infection was recorded. No other complication was documented. The technique described is similar to the one suggested by Peled, although some useful tips were added, namely the use of sutures, not only to fix the implant but also to drive it into the harvested pocket. In addition, larger absorbable "left in place" sutures were used, avoiding accidental implant dislocation during their removal. Further studies are required to gain a more complete understanding of the effectiveness and reproducibility of this surgical technique.

An easy and effective technique for silicone facial implant insertion and fixation to periosteum / Rauso, R.; Giudice, G. L.; Faro, C. L.; Nicoletti, G. F.; Fragola, R.; Sesenna, E.; Tartaro, G.. - In: APPLIED SCIENCES. - ISSN 2076-3417. - 10:18(2020), p. 6508. [10.3390/APP10186508]

An easy and effective technique for silicone facial implant insertion and fixation to periosteum

Sesenna E.
;
2020-01-01

Abstract

In this paper, we present a simple way to place the implant into a harvested pocket and to subsequently fix it percutaneously. Eighteen patients (1 male, 13 females, 4 transgender), underwent facial implant placement; a total of 31 implants were placed (1 pair of angles of the mandible implants, 12 pairs of malar/sub-malar implants, and 5 chin implants). The intraoral approach was performed on 15 patients, and on the remaining three patients, the sub-ciliary lower lid approach was preferred. Patients were followed up for at least one year with a maximum follow-up of seven years (mean 1.8 years). In all the cases, except one, patients healed without complications. One case of implant displacement and infection was recorded. No other complication was documented. The technique described is similar to the one suggested by Peled, although some useful tips were added, namely the use of sutures, not only to fix the implant but also to drive it into the harvested pocket. In addition, larger absorbable "left in place" sutures were used, avoiding accidental implant dislocation during their removal. Further studies are required to gain a more complete understanding of the effectiveness and reproducibility of this surgical technique.
2020
An easy and effective technique for silicone facial implant insertion and fixation to periosteum / Rauso, R.; Giudice, G. L.; Faro, C. L.; Nicoletti, G. F.; Fragola, R.; Sesenna, E.; Tartaro, G.. - In: APPLIED SCIENCES. - ISSN 2076-3417. - 10:18(2020), p. 6508. [10.3390/APP10186508]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2887451
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact