Legionella spp. is a ubiquitous intracellular microorganism in aquatic environments both natural and artificial. Although Legionella pneumophila sg 1 and sg 6 are the main causes of disease, other species have recently been associated with cases of legionellosis. Since 2000, some international documents related to the control and prevention of Legionnaires’ disease have been issued, providing different environmental matrices’ sampling, but not for air. To date, the control on water mains is preferred; however, air sampling could be a useful tool for exposure evaluation. To sample biological particles in the air, active and passive methods can be used. Several studies have compared the values of microbial counts obtained with these sampling methods, attaining discordant results. Based on this scientific background and on the experience about Legionella spp. contamination and air microbial sampling in health care environments, GISIO-SItI, AIA, and SIMPIOS promoted two multicenter studies focused on identifying a standardized sampling protocol to detect the airborne contamination coming from water sources contaminated with Legionella spp.

Legionella indoor air contamination in healthcare environments / Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Albertini, Roberto; Pasquarella, Cesira Isabella Maria; Agodi, A.; Coniglio, M. A.; Albertini, R.; Baldovin, T.; Cristina, M. L.; Spagnolo, A. M.; Dâ errico, M. M.; Delia, S. A.; Laganã , P.; Giuliano, A.; Liguori, G.; Guida, M.; Montagna, M. T.; De Giglio, O.; Diella, G.; Divenuto, F.; Rutigliano, S.; Caggiano, G.; Moro, M.; Mura, I.; Deriu, M. G.; Napoli, C.; Torre, I.; Privitera, G.; Casini, B.; Romano Spica, V.; Valeriani, F.; Rossini, A.; Tardivo, S.; Sembeni, S.; Torregrossa, M. V.; Pennino, F.; Cannova, L.; Villafrate, M. R.. - (2017), pp. 63-71. [10.1007/978-3-319-49160-8_6]

Legionella indoor air contamination in healthcare environments

ALBERTINI, Roberto;PASQUARELLA, Cesira Isabella Maria;
2017-01-01

Abstract

Legionella spp. is a ubiquitous intracellular microorganism in aquatic environments both natural and artificial. Although Legionella pneumophila sg 1 and sg 6 are the main causes of disease, other species have recently been associated with cases of legionellosis. Since 2000, some international documents related to the control and prevention of Legionnaires’ disease have been issued, providing different environmental matrices’ sampling, but not for air. To date, the control on water mains is preferred; however, air sampling could be a useful tool for exposure evaluation. To sample biological particles in the air, active and passive methods can be used. Several studies have compared the values of microbial counts obtained with these sampling methods, attaining discordant results. Based on this scientific background and on the experience about Legionella spp. contamination and air microbial sampling in health care environments, GISIO-SItI, AIA, and SIMPIOS promoted two multicenter studies focused on identifying a standardized sampling protocol to detect the airborne contamination coming from water sources contaminated with Legionella spp.
2017
978-3-319-49159-2
978-3-319-49160-8
Legionella indoor air contamination in healthcare environments / Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Albertini, Roberto; Pasquarella, Cesira Isabella Maria; Agodi, A.; Coniglio, M. A.; Albertini, R.; Baldovin, T.; Cristina, M. L.; Spagnolo, A. M.; Dâ errico, M. M.; Delia, S. A.; Laganã , P.; Giuliano, A.; Liguori, G.; Guida, M.; Montagna, M. T.; De Giglio, O.; Diella, G.; Divenuto, F.; Rutigliano, S.; Caggiano, G.; Moro, M.; Mura, I.; Deriu, M. G.; Napoli, C.; Torre, I.; Privitera, G.; Casini, B.; Romano Spica, V.; Valeriani, F.; Rossini, A.; Tardivo, S.; Sembeni, S.; Torregrossa, M. V.; Pennino, F.; Cannova, L.; Villafrate, M. R.. - (2017), pp. 63-71. [10.1007/978-3-319-49160-8_6]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11381/2830196
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? ND
social impact